5.4
Connecting the hose lines
See chapter "Application example" for an example of how to route the hoses
from the product to the tank.
 Verify that the hoses are resistant to the stored liquid and its vapours.
1. Use oil- and water-resistant plastic hoses 6 x 2 mm for the measuring line
(red), the suction line (transparent) and the pressure line (transparent).
2. In outdoor or underground applications, install the hoses in suitable liquid-
tight, shock-resistant and weather-resistant protective pipes.
3. The hose lines must have the full cross section over the entire length;
there must be no bends and indentations.
4. Do not install any shut-off fittings.
Mounting
2. Plug the EnOcean® wire-
less module into the slot.
When plugging in the
wireless module, ensure
the following:
- The position of the
antenna must be at the
right side (close to the
housing wall).
- All pins must be inserted
into the female connec-
tor.
3. Push the antenna of the
EnOcean® wireless mod-
ule into the two housing
openings of the product.
4. Close the cover of the
product.