Never use an old connector when installing a new range. If the hard-piping
method is used, you must carefully align the pipe; the range cannot be moved
after the connection is made.
To prevent gas leaks, apply pipe-joint compound or wrap pipe-thread tape with
Teflon on all male (external) pipe threads.
1. Install a manual gas line shut-off valve in the gas line in an easily accessed
location outside of the range.
Make sure everyone operating the range knows where and how to shut off the
gas supply to the range.
2. Install male 0.5 in (1.3 mm) flare union adapter to the 0.5 in (1.3 mm) NPT
internal thread at the regulator inlet. Use a backup wrench on the regulator
fitting to avoid damage.
When installing the range from the front, remove the 90° elbow for easier
installation.
3. Install male 0.5 in (1.3 mm) or 0.75 in (1.9 mm) flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care to back up the shut-
off valve to keep it from turning.
4. Connect flexible metal appliance connector to the adapter on the range.
Position range to permit connection at the shut-off valve.
5. When all connections have been made, make sure all range controls are in the
off position and turn on the main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in the system.
WARNING
Do not use a flame to check for gas leaks to prevent death, personal injury,
explosion, and/or fire hazard.
When using test pressures greater than 1/2 psig to pressure-test the gas supply
system of the residence, disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of 1/2 psig or less to test the gas
supply system, simply isolate the range from the gas supply system by closing the
individual shut-off valve.
WARNING
Do not exceed 25 ft-lbs of torque when making gas line connections. Overtightening
may crack the pressure regulator resulting in a gas leak.
Install_NX58R4311SS_AA_DG68-01153A-00_EN.indd 23
Do not tighten flare union adapter to the NTP internal thread at the
regulator too hard.
To prevent gas leaks, apply pipe-joint compound in the vicinity of the joints.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
NOTE
•
If your area requires a rigid pipe hookup, contact a qualified installer, service
agency, or gas supplier.
•
The gas shut-off valve should be installed in an accessible location in the gas
piping, external to the appliance, for the purpose of turning on or shutting off
the gas to the appliance.
0.5 in or 0.75 in Gas Pipe
Gas Shut-
Off Valve
Adapter
Flex
Connector
(6-ft max.)
Adapter
Tubing Line to Oven Burner
Control Valve
Tubing Line to
Cooktop Control
Manifold
Pressure Regulator
English 23