SEMI-FLUSH MOUNTING AND WIRING INSTRUCTIONS
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures
meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Thread mounting screws (D) into cross bar (A) approximately 1/4 inch (see fig. 1).
3. Secure cross bar (A) to outlet box (B) with outlet box screws (C).
4. Slide column (J) and cap (M) down over nipple 2 (G2).
5. Thread nipple 2 (G2) onto coupling (H). Do not twist or kink wires.
6. Select number of stems (E) to install based on desired fixture length, then connect stems (E).
7. Thread fixture wires up through stem(s) (E), coupling (F), and canopy (G).
8. Thread stem (E) onto the nipple 2 (G2), then secure the stem (E) into the coupling (F).
9. Identify color coding of fixture wires (see fig. 2).
10. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet
box wire. Do not twist wires.
11. Fit wire connector (O from fig. 1) over wires and twist until there is a firm connection. If wire
connector (O) easily comes off, reattach and check again for a firm connection.
12. Repeat steps 10 and 11 with the white (group B from fig. 2) fixture wires and outlet box wires.
13. Partially thread green grounding screw (P) into side hole (Q) on cross bar (A) (see fig. 1).
14. Wrap ground wire from fixture around green grounding screw (P) leaving enough excess wire to then
connect ground wire and outlet box wire with wire connector (O), if applicable.
15. Tighten green grounding screw (P). Do not over tighten.
16. Tuck wires inside outlet box (B).
FIXTURE ASSEMBLY INSTRUCTIONS
Warning: This fixture is for indoor use only.
1. Raise canopy (G) to ceiling, allowing mounting screws (D) to protrude through openings in
canopy (G), and secure into place with cap nuts (I) (see fig. 1)
2. Raise shade (R) up to socket assembly (S) and secure with retaining ring (T).)
NOTE: if retaining ring(s) (T) was preinstalled, remove before installing glass shade(s) (R).
3. Install lamp(s). Do not exceed recommended wattage.
4. Thread hex nut (X) onto nipple 3 (G3), then thread nipple 3 (G3) into lower fixture
base (Y). Place decorative cap (V) over nipple 3 (G2) and secure with finial (U).
5. Turn power back on at circuit box.