Diagram 1

When hydraulic system 1 has been set, the display is as follows:
If active, it indicates that the three-way
valve is turned in the heating circuit.
It flashes when the thermo-stove is
actually exchanging heat in the circuit
10:00
t on
OFF
Active external thermostat
If active, it indicates the circuit request
- boiler setting: press P1; to change values press P1 and P2;
- boiler water setting: press P4; to change values press P4 and P5;
- room t. setting: act on the external thermostat. When t on appears, the thermostat request is active; with t off no request is active.

Diagram 2

When hydraulic system 2 has been set, the display is as follows:
If active, it indicates the Buffer tank request
- buffer tank setting: press P4; to change values press P4 and P5;

Diagram 3

When hydraulic system 3 has been set, the display is as follows:
The segments active in the second line,
under the sanitary and heating symbols,
indicate a request by the Boiler, the Buffer
tank or both
10:00
PuFF
OFF
Displays Buffer tank temperature
- boiler setting: press P1; to change values press P1 and P2;
- buffer tank setting: press P4; to change values press P4 and P5;
Model Aqva 10 Use and Maintenance Manual
If active, it indicates that the three-way valve
is turned in the Boiler circuit. It flashes
when the thermo-stove is actually
exchanging heat in the Boiler
H2o
ton - request
toff - no request
e
10:00
PuFF
OFF
Displays Buffer tank temperature
If active, it indicates that the three-way valve
is turned on the Boiler circuit. It flashes when
the thermo-stove is actually exchanging heat
in the Boiler
50°C
Displays Boiler temperature
10:00
boil H2o
OFF
Displays Boiler temperature
It indicates if the thermo-stove is
operating in "Summer" or "Winter" mode
10:00
52°C
OFF
Displays thermo-stove temperature
10:00
boil
45°C
OFF
Rev.0 04/03/2019
Page70
If active, it indicates the Boiler request
It indicates if the thermo-stove is
operating in "Summer" or "Winter" mode
10:00
52°C
55°C
OFF
Displays boiler H2O temperature
55°C
If active, it indicates that the three-way valve
is turned on the Buffer tank circuit. It flashes
when the thermo-stove is actually exchanging
heat in the Buffer tank
10:00
H2o
55°C
OFF
Displays thermo-stove temperature
EN