Télécharger Imprimer la page

Pujol Marathon Pro Q III Mode D'emploi page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

marathon Pro
Conditions of Use
The Marathon PRO Q III drive unit is designed and intended for installation on sliding doors within the weight limits listed in the table of
technical specifications. Automatismos Pujol disclaims any responsibility if the drive unit is installed in any other kind of installation not
covered in this manual.This automatic device must be installed, connected and commissioned by qualified and trained personnel.
To avoid accidents during installation, consult the Chapter on Regulations
The unit must only be connected to the mains power after the installation operations described below have been completed and before
the travel direction test, and travel programming.
When the rotation direction test and travel programming operations are carried out, the installer must be out of the danger area and
keep a safe distance from the path of the door.
Installation Specifications
The drive unit must be installed in such a way as to require special tools for disassembly. When doors with gaps in them are installed,
there must be no fixed structures close to the door that could create danger of entrapment.
Check that the structure of the door and the pillars are sufficiently robust and that during movement there are no friction points, or
danger of entrapment or shearing.
Photocells or sensors shall be installed where required by the applicable regulations
Consult the Chapter on Regulations to avoid accidents during maintenance
Maintenance operations should be done only once the device has been switched to safety mode. This is done by opening the
single-pole switch on the start-up control and making sure that this cannot be switched back during the maintenance operation
(by using suitable signage, locking the switch, etc.)
Note to Users:
Maintenance operations on the device or inspection by non-qualified personnel is prohibited.
WARNING:
1. It is very important for the safety of persons to follow these instructions carefully. Incorrect installation or improper use can cause
serious injury to people.
2. Read the instructions carefully before installing the product.
3. Keep the instructions for future reference.
4. This product is intended strictly for the use described in this manual. Any other than the intended use may adversely affect the
operation of the product and/or be a source of danger.
5. Do not install the equipment in an explosive atmosphere; the presence of flammable gas or fumes is a serious safety hazard.
6. All mechanical construction components used should comply with the provisions of Standards EN 12604 and EN 12605.
7 The manufacturer is not liable for failure to comply with good practices in the manufacture of the gates or doors to be motorized,
or for any deformation that may occur to them during use.
8.The manufacturer is not liable for any loss or damage deriving from misuse of the product.
9. It is advisable to use at least one warning light and lighted notice permanently fixed to the frame structure, as well as those
recommended in point 21.
10. No liability will be accepted regarding safety and malfunction of the automation system if components manufactured by third
parties are used.
11. Use only original parts for maintenance purposes
12. Do not modify the components comprising the automation system.
13. The installer must supply all information concerning the emergency operation of the system and give the user the "User's
Manual" that accompanies the product.
14. The packaging materials (plastic, polystyrene, and the like) must not be left within reach of children as they are potential
sources of danger.
15. Do not allow children and adults near the product during operation.
16. Keep remote controls or other transmitters away from children to prevent the automatic device being accidentally activated.
17. Disconnect the power supply before carrying out any work on the installation.
18. Fit a single-pole isolating switch with a distance of at least 3 mm between the contacts of the device. It is recommended that a 6-
amp single-pole magneto-thermic circuit breaker is used.
19. On beginning the installation, ensure that a differential switch with threshold of 0.03 is available for use
20. Ensure that the installation is properly earthed.
21. EN 12978 standard safety standards protect potentially dangerous areas against mechanical movement hazards, such as
entrapment, dragging, and shearing.
Q
III
PRELIMINARY RECOMMENDATIONS
English
7

Publicité

loading