Leister LHS 15 Instructions D'utilisation page 26

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
Device description
LHS 15, LHS 21 S, LHS 21 L, LHS 41 S, LHS 41 L:
CLASSIC, PREMIUM, SYSTEM
3
5
1
CLASSIC, PREMIUM, SYSTEM
1 Mounting straps
2 Connection housing cover
3 Screws for connection housing
4 Heating element tube
5 Cable gland for mains connection
(mounted ex works)
6 Locking screw
(enclosed in the connection housing)
7 Cable gland for interface
8 Air inlet
Preparation
• Remove LHS air heater from the packaging.
• Remove the connection housing cover (2) by loosening the screws (3).
• Remove warning slip,
• Remove locking screw (6).
• If no interface is connected, the cable gland (7) must be removed and the locking screw (6) mounted.
Installation
• The installation must ensure that
– only cold air is supplied.
– no excess (heat) residue builds up.
– the device is not subject to jets of hot air from another device.
• Protect the device from mechanical vibrations and shocks.
• Fasten the device on the mounting straps (1).
• For installation dimensions, see pages 3, 4, 5, 6 (Size)
26
2
3
3
1
3
1
read carefully and keep at hand for consultation.
LHS 61L, LHS 61 S:
CLASSIC, PREMIUM, SYSTEM
4
5
PREMIUM, SYSTEM
9 Potentiometer for temperature setting
SYSTEM
10 Display for showing the setpoint and actual
values (°C or °F)
2
1
4

Publicité

Table des Matières
loading

Table des Matières