3.2 Programming a calibration value
Entering into programming mode does not clear the previous setting, so you can update a
previously stored calibration value easily.
All settings are stored in Flash memory. No need to repeat programming after the battery or
the SH box has been disconnected.
1. Press BOTH buttons on the unit until [ L ] is indicated.
2. The Sign of the calibration value is blinking:
[ -] : Negative
[ P ] : Positive
To toggle the Sign, press the SET button
If the Sign you set is Negative, you will program 3 digits (max value: 99.9)
If Positive sign was selected, you need to enter 5 digits (max value: 9999.9)
You need to enter all digits (including the leading zeros), so e.g. you would enter -07.5 if
you wanted to program -7.5%
3. Press SEL to proceed to the first digit of the calibration value.
[ n ] (next) is shown momentarily, then the value of the first digit is blinking.
Press SET repeatedly until the desired value is shown.
Repeat this step until all digits are entered.
4. After the last digit has been entered, press SEL to exit from programming mode.
[ 0 ] (over) is shown momentarily, then the unit will display the programmed digits in
order, just like any time ignition is turned on.
3.3 Reviewing the calibration value in use
Whenever the ignition key is turned on, the unit will show the following information in order:
-
Memory bank in use: either [ A ] or [ B ]
-
Sign of the Calibration value: [ - ]: Negative, [ P ]: Positive
-
Calibration value without leading zeros
-
Conversion mode active [ C ] or not (blank)
Examples:
[ A 0 ] means A memory bank is active with no calibration (factory default)
[ A - 7.5 ] means A memory bank is active with -7.5% calibration
[ A – 1 2.5C ] A bank is in
[ A P 5.0 ] means A memory bank is active with +5.0% calibration
[ b P 6 2 3 4. 5C ] B bank, +6234.5% and Km/h conversion is enabled
3.4 Reset
The is no need to clear the memory before programming a new calibration value. You can
overwrite the previous setting easily.
However, if you wish to clear all settings and go back to defaults:
Press BOTH buttons on the unit ant keep it depressed unitil [ E ] is indicated.
When the unit is powered up with default parameters, [ A 0 ] is displayed.
It means A memory bank is active with no calibration. The unit will work in Transparent mode,
i.e. the speedometer will read the same as with no SH installed.
3.5 Switching between A and B calibration value
Press SET until the active memory bank ([ A ] or [ b ]) is displayed and keep it depressed for one
more sec, until the value toggles.
When you program a calibration value (chapter 3.2), you can program the value in the active
memory bank only.