Error And Tamper Monitoring; Time Conditions; Factory Settings - Abus FUBW50120 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62
Functions and displays
Note:
The 3-minute rest period is now active.

Error and tamper monitoring

The detector continually monitors error and tamper states and reports all events to the receiver
component. The following is monitored:
• Tamper contact:
The detector's tamper contact is continually monitored.
• Battery voltage:
The detector monitors the battery voltage under load conditions and reports faults to the
receiver component.
• Supervision
The detector continually sends supervision messages to the alarm panel.

Time conditions

The detector was designed so that changes are detected if they last at least 400 ms (EN50131-1
Chapter 8.9.1 and EN50131-3 Chapter 8.9 and Annex B).
Breaking and entering, intrusion and tampering signals must last at least 400 ms.
The detector was designed so that changes to the fault statuses (fault signals) are detected if they
last at least 10 s (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and Annex B).

Factory settings

The detector has no special factory settings.
However, the placement of the potentiometer for the microwave range and the CON1 A jumper for
"animal-proofing" should be observed.
When not in use, unprogram the detector from the receiver component.
Before programming the detector into a new receiver component, unprogram the detector from the
previous receiver component. This will prevent a tamper alarm from being accidentally triggered in
the previous control unit.
56 |
E N

Publicité

Table des Matières
loading

Table des Matières