3.2 Accessories
18 Module 1 for generating straight wave fronts
19 Module 2 for generating 2 interfering circular
waves
20 Module 3 for generating circular waves
21 Extension tube for connection to module 1
4. Technical data
Dimensions:
Tank structure:
Projection screen:
Frequency range:
Power supply:
Stroboscope lighting:
5. Operation
It is recommended that the experiments be car-
ried out using distilled water.
Place the ripple tank upon a horizontal sur-
face, making sure it is not subject to any
shocks.
Use the spirit level and the height-adjustable
feet to align the ripple tank horizontally.
Connect the drainage outlet hose in its
clamp on the tank in such a way that in it
points vertically upwards.
Attach the stand rod with the stroboscope to
the side of the tank with the aid of the mag-
netic holder.
Connect the stroboscope to the control unit
by means of the three-pole cable and plug
3
400x300x320 mm
approx.
2
375x320 mm
approx.
1 – 60 Hz, continuously
adjustable
12 V DC via plug-in
power supply 100 – 240 V
LED
22 Hose
Immersion bodies for setting up a single slit
23
and a double slit
Immersion bodies for reflection and refraction
24
(prism, biconcave lens and biconvex lens)
the control unit into the mains using the
plug-in power supply.
Set the stroboscope frequency to zero ini-
tially.
Align the height and position of the strobo-
scope in such a way that the tank is fully il-
luminated.
Insert the required exciter module into the
holder and secure it with the knurled screw.
Set the height of the exciter module by ad-
justing the height of the holder and secure it
to the back of the fitting with the help of the
knurled screws.
Fill the tank with distilled water. For experi-
ments on refraction, fill the tank to approx. 1
mm over the level of the immersion bodies.
For other experiments, fill to approx. 5 mm
over the level of the immersion bodies.
Use the drainage hose to empty the tank
after the experiment.
Thoroughly dry the apparatus to prevent
forming of lime scale deposits.
Lay the appropriate immersion bodies in the
tank to set up a reflecting barrier or single
and double slits.