ATTENTION
Please read the following instructions carefully to ensure that mounting operation will be carried out correctly. These instructions
should be properly preserved for future reference.
CAUTION
1. The product must be installed by qualified technicians. The power supply must be cut before installation.
2. The installation wiring must be 2x 1.0 mm² at least and wired in accordance with the latest IEE electrical regulations or the national requirements.
(Recommended type of cable is H05RN-F)
3. Do not touch the electronic circuit and its components.
4. Do not touch the LEDs while installing or maintaining.
5. The LED light source of the lamp cannot be replaced. The complete product must be replaced if the light source is defect.
TECHNICAL DATA
Supply voltage: AC 220-240V 50/60Hz
Light source: LED SMD2835
Operating temperature: -20°C – +50°C
TECHNICAL INFORMATION
Article no.
Power
Color temperature switchable
40009850
15W
3000K <—> 4000K
40009851
16W
3000K <—> 4000K
MICROWAVE SENSOR - DESCRIPTION
Detection zone max. (d x h): 14m x 6m
Detection sensitivity: 25% - 100%, adjustable
Hold time: 5sec - 30min, adjustable
Daylight 1: 5 - 15Lux, adjustable or disable
Daylight 2: 35 - 150Lux, adjustable or disable
(with daylight priority)
Hold time: 5 - 30sec - 1 - 5 - 15 - 30min (adjustable)
Hold time orientation lighting:
0 - 10 - 20 - 30 - 60 - ∞ min (adjustable)
Mounting height: 6m max.
Motion detection: 0.5 ~ 3m/s
Detection angle: 150° (wall installation),
360° (ceiling installation)
8
Light output
MW sensor
1400Lm - 1500Lm
-
1400Lm - 1500Lm
Yes
Wall mounting detection area (Unit: m)
Suggested installation height: 1 - 1.8m
www.prolumia.eu
370
Ceiling mounting detection area (Unit: m)
Suggested installation height: 2.5 - 6m