TYPE
Name
Location
Volume (l)
Voltage (V)
Heating performance (W)
Current input (A)
Heating time
From 15ºC to 65ºC (h)
65ºC
Standby energy use at
(Wh/24h)
Water connection
Weight empty (kg)
Rated water pressure (MPa)
Largest opening pressure of
safety valve (MPa)
In-built safety controlling
elements
Other protection
Applicable touch protection: Touch protection class I. It can be connected to electric system supplied with protective earthing as defined in IEC 60364 .
The most important instructions regarding the product are the following: EN 60335-1, EN 60335-2-21. Storage and transportation requirements
regarding the product is EN 60721-3.
8. TECHNICAL DATA
AQ30ErP
AQ50ErP
Hot water tank with closed internal circulation system
30
50
1,0
1,8
0,77
0,89
16,2
19,7
AQ80ErP
AQ100ErP
Vertical wall
80
100
230~
1800
10
2,8
3,5
1
1,3
G1/2
27,4
29,4
0,6
0,7
Built-in temperature control device /
combined control safety-valve
Active anode based corrosion protection
13
AQ120ErP
AQ150ErP
120
150
4,2
5,3
1,5
1,7
32,4
38,5
AQ200ErP
200
2400
16
5,3
2,53
52

Publicité

loading

Ce manuel est également adapté pour:

Aq50erpAq80erpAq100erpAq120erpAq150erpAq200erp