7. RETIRING THE MACHINE FROM ACTIVE DUTY
Removing the machine from the market must only be done by authorized te-
chnicians.
To remove the machine from active duty it is necessary to eliminate the pres-
sure from the hydraulic circuit, turn of the machine acting on the RCD, then
unplug power cord and
process environment corrosive substances.
After completing the procedures of the former paragraph, put the machine in a
safe place, outside the reach of children and irresponsible persons.
The machine should be shipped back to the manufacturer or to an authorized
recycling centre for electric and electronic equipment (EEE).
Do not abandon in the environment.
8. CLEANING OPERATIONS
Daily maintenance and cleaning operations:
During the service:
Clean the steam
pipe with a damp
cloth of specifi c use
before and after
each use, in order
to avoid incrusta-
tion and formation
of germs and bac-
teria.
End of service:
To make the in-
ternal cleaning of
the groups, place
specifi c detergent
in the blind fi lter
and perform the
washing, press the
"continuous" button
( ) for the water
outlet.
65
End of service:
To clean the fi lters
and fi lter holder,
the fi rst ones must
be uncoupled, wash
these components
with a scouring pad
in fi ber material
and a lot of water.
End of service:
Clean the outside
of the sieves and
seals of each group
with a specifi c