Unlearning the relay from the network:
NOTE: Ensure to disconnect mains power prior
to removing lid and unscrewing the unit from its
installation position.
1. To remove a relay from the network you will need
to perform a button press sequence consisting of a
short press followed by a long press.
2. Using a ballpoint pen, on the button on the back of
the relay, briefly push and release and then push and
hold (for 5 seconds) the button, then release.
3. After the button has been released, the "Blue" LED will
flash 2 long flashes, followed by a further single flash to
illustrate that the relay has successfully been 'un-learned'
from the network. If the unlearn button is not pressed
correctly the "unlearn process" will fail. If you do not see
the correct flash sequence, repeat the process.
MIXED SYSTEM COMPATIBILITY
Both relays are capable of mixed system operation.
This means both hardwired and wireless alarms can
be installed onto a single network which is then linked
with an appropriate relay.
Ensure there is only one wireless connection into each
alarm network. For example if you have a hardwired
network upstairs and a wireless network downstairs,
only one of the hardwired alarms should be
connected with a wireless alarm (upstairs) and linked
into the wireless network (downstairs), connecting
both systems. The relay can then link into any one of
the alarms on the network as follows.
For RLYM-1 – Hardwire interconnect required into any
hardwired alarm on the network
For WRLYM-1 – Wireless interlink required into any
wireless alarm on the network
See diagram for wiring option using surface trunking
and knockout segments on the side of the unit.