11. Maintenance
In order to perform maintenance, we recommend the use of protection equipment, such as gloves.
Always disconnect the power plug of the socket before performing any service or maintenance.
Technical maintenance and other actions should be carried out by authorised technicians only, using original spare parts. The
manufacturer assumes no responsibility resulting from incorrect use of the product or the non-compliance of the instructions contained
in this manual.
The UV-C lamps have about 18000 hours of service life. The equipment will automatically send lamp-ending life cycle warnings to advice
to replace lamp within: 500 h, 250 h, 100 h, 50 h, 25 h and 10 h. When lamp reaches the end of its life, the equipment will not operate
(more in 9.3.1 Alarms).
Table 4: WonderXPure maintenance table.
Germicidal lamp
Pre-filter
Photocatalytic filters
How to remove lamps
11.1.
If any of the lamp end life-cycle or reports a failure alarm, carefully remove the lamp from the equipment.
11.1.1.
Proceadure for WonderXPure 01
 Make sure the WonderXPure is disconnected from the power source;
 Remove the six screws on the back panel using a screwdriver;
 Using safety gloves, carefully pull back the lower part of the lamp, until it disconnects from the lamp holder;
 Grab the lower part of the lamp, already free, in a vertical movement gently retrieve the lamp from the fixed lamp guard in the
top.
11.1.2.
Proceadure for WonderX Pure 02
 Make sure the WonderXPure is disconnected from the power source;
 Remove the ten screws on the lateral panel using a screwdriver;
 Using safety gloves, carefully pull back the right side of each lamp, until it disconnects from the lamp holder;
 Grab the lower part of the lamp, already free, in a vertical movement gently retrieve the lamp from the fixed lamp guard in the
top.
Lamp Installation
11.2.
Make sure the WonderXPure is disconnected from the power source.
11.2.1.
Proceadure for WonderXPure 01
Carefully fit the lamp in the top
lamp
guard
in
a
vertical
movement.
Figure 6: lamp installation scheme for WonderXPure 01.
Notice d'Utilisation
Bedienungsanleitung
Recommended cleaning period
Once every three months
---
Once every three months
Gently push the lamp forward
to fit the bottom lamp holder.
I0003-2021-MNS-MKT
Replacement period
Only if damaged or if life-cycle ends
Replace once every six months
---
Insert the lateral panel and place
the six screws accordingly.