2. INSTALLATION
IMPORTANT For the correct operation of gesture commands, do not install the device in places
exposed to direct sunlight because the IR sensor is sensitive to light.
•
Embed the flush-mounting box Mod. 503 in the wall or the flush-mounting box Ø 60 at the height shown
in the following drawing.
The flush-mounting box Mod. 503 can be installed either horizontally or vertically.
•
Fix the bracket to the mounting box as indicated.
•
Make the connections to the terminal board.
•
Fix the door phone to the bracket.
•
Remove the protective film from the display.
2 x M3.5 x 19 mm
provided
2.1. DESCRIPTION OF TERMINALS
}
S-
Call repeater
S+
]
Panic alarm
PANIC
]
Floor call
FC
3. WIRING INSTRUCTIONS
RJ45 Ethernet Cable
The Ipercom system has been designed to work with the EIA/TIA 568B standard.
•
Plug the cable into one of the RJ45 connectors with the Urmet logo.
•
Insert the wire in its guide, according to the provided colour code (Standard T568B).
6
Box
Mod. 503
1
2
2 x 2.9 x 13 mm
countersunk screws
Box
Ø 60 mm
DS1761-002