RESISTANCE
Maximum open circuit voltage: 3.2V
Overload protection: 250V DC or rms for all levels.
OPERATING INSTRUCTIONS
WARNING: To avoid electrical shock hazard and/or
damage of the instrument, do not measure voltages
that might exceed DC 600V or AC 600V above earth
ground. Before using instrument, inspect test leads,
connectors and probes for cracks, breaks or crazes
in the insulation.
DC VOLTAGE MEASUREMENT
1. Connect red test leads to "V Ω mA" jack, black
leads to "COM" jack.
2. Set switch to desired DCV position. If the voltage to
be measured is not known beforehand, set switch
to the highest range and reduce it until satisfactory
reading is obtained.
3. Connect leads to device or circuit being measured.
4. Voltage value will appear on the display along with
the voltage polarity.
78207i.indd 8
Range
200 ohm
2k ohm
20k ohm
200k ohm
2M ohm
Resolution
0.1 ohm
1 ohm
10 ohm
100 ohm
1k ohm
Accuracy
±0.8% of rdg ±5D
±0.8% of rdg ±2D
±0.8% of rdg ±2D
±0.8% of rdg ±2D
±1.0% of rdg ±5D
02-04-19 14:0