Section 8. Twelve (12) Volt Installation - Jandy Pro Series WPLV100WS30 Guide D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series Underwater Pool and Spa White Lights | Installation Manual
®
f.
Tighten the eight (8) Phillips head screws for pool
light or the six (6) Phillips head screws for spa
light in alternating cross-pattern. Torque screws to
approximately 20 in-lbs. Do not over-tighten.
g. Discard the old gasket.
6.
Reinstall the Jandy Pro Series Light into niche
fixture.
a. Coil four (4) feet of cord around the fixture and
place the light assembly into the niche.
b. Engage the retainer tab on the bottom of the face
ring, then pivot the top of the fixture inward and
tighten the special pilot screw.
WARNING
Use only the special pilot screw provided with this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided
could create an electrical hazard, which could result
in death or serious injury to pool or spa users,
installers or others due to electrical shock.
7.
If pool or spa is empty, fill pool or spa until the
underwater light is completely submerged in
water before operating the light for more than 10
seconds. Turn on main switch or circuit breaker, as
well as the switch, which specifically operates the
underwater light, to check for proper operation.
WARNING
Never operate this underwater light for more than
10 seconds unless it is totally submerged in water.
Without total submersion, the light assembly will get
extremely hot, which may result in serious burns
or in breakage of the lamp or lens. This may result
in serious injury to pool or spa users, installers, or
bystanders or in damage to property.
Section 8. Twelve (12) Volt
Installation
A separate 12-Volt AC Transformer is required on all
12-Volt Models. Use an appropriately sized transformer
for your model light.
NOTE For optimum performance Jandy Pro Series
recommends to use one transformer per 12-volt
light.
ENGLISH
To ensure compliance with the National Electrical
Code
(NEC
) in the US (Canadian Electrical Code
®
®
(CEC) in Canada), and to reduce the risk of electric
shock which could result in serious injury or death, use
only a transformer that has been listed or recognized by
a Nationally Recognized Testing Laboratory (NRTL) for
pool/spa application.