The RA116A Protectorelay Oil Burner Control is a
stack-mounted oil primary control that provides line volt-
age switching of intermittent ignition burners (formerly
called constant ignition burners). The RA116A is used
with a Honeywell series 10, 3-wire thermostat; any 24V, 2-
wire thermostat; or any line volt thermostat or controller.
The thermostat heat anticipator setting must be adjusted to
0.4A for 24V thermostats only.
If the burner fails to ignite during startup, a safety switch
Honeywell
R116A,B
R124A,B
R134A
R168A
R494A
RA116A,B
RA416A
a
RA816A,D
Penn
664
670
680
a
When replacing a model with an F or O terminal to power a clogged filter indicator light, provide a separate transformer
for the light.
b
A Detroit 3-wire thermostat must be replaced by a 2-wire thermostat with a suitable heat anticipator.
WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings given in these instructions and on
the product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service tech-
nician.
4. After installation is complete, check out product
operation as provided in these instructions.
RA116A Protectorelay
Application
TABLE 1—RA116A CROSS-REFERENCE.
White Rodgers
603
611-1
611-31
611-33
615
6L18
ITT General
5200
R96A102A
R96G102DC
Installation
C.H. • 2-92 • © Honeywell Inc. 1992 • Printed in U.S.A • Form Number 69-0650B
Oil Burner Control
trips and locks out the burner system. To restart, the safety
switch must be reset manually. If the burner flame goes out
during burner operation, the Protectorelay Control locks
out unless the flame is reestablished within the 75 second
(nominal) safety switch timing. If the power supply fails,
the control returns to the starting position, ready to restart
when power is restored.
The RA116A is designed to replace existing controls
listed in Table 1. Ensure the electrical ratings and element
insertion length are suitable before installing.
General Electric
A101B2
CR7865
Mercoid
JM
CAUTION
!
1. Do not bend contact arms or stops on the
Pyrostat detector mechanism or make any ad-
justments other than those given in the instruc-
tions.
2. Remove the cardboard packing behind the
drive shaft lever by pushing the packing up and
pulling it straight out over the top of the lever.
Do not remove packing by pulling sideways.
3. Ensure all wiring complies with applicable
codes and ordinances.
General Perfex
5200
5300
Detroit
b
CA701
b
CA702

Publicité

loading

Sommaire des Matières pour Honeywell R116A

  • Page 1 3. Ensure all wiring complies with applicable 4. After installation is complete, check out product codes and ordinances. operation as provided in these instructions. C.H. • 2-92 • © Honeywell Inc. 1992 • Printed in U.S.A • Form Number 69-0650B...
  • Page 2 Fig. 1—Mounting and location guidelines. DRILL HOLES AND FASTEN FLANGE WITH SCREWS FURNISHED STACK CUT 1-3/8 INCH [35 MM] HOLE IN STACK TIGHTEN LOCK SCREW INSERT BIMETAL ELEMENT IN CENTER OF STACK IN DIRECT PATH OF HOT FLUE GASES DO NOT FORCE COLLAR OF MOUNTING FLANGE PAST STOP. M1586B MOUNTING (See Fig.
  • Page 3 3. Open the hand valve in the oil supply line. Fig. 2—RA116A wiring diagram with 24V, 3-wire 4. Set the limit control and thermostat to call for heat. thermostat. 5. Close the line switch. The burner should start. CHECK THE SAFETY FEATURES (HOT) Simulate flame failure: 1.
  • Page 4 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, Minnesota 55422 Scarborough, Ontario M1P 2V9...
  • Page 5 3. S’assurer que tous les raccordements présentes instructions. respectent les codes et règlements locaux en vigueur. C.H. • 2-92 • © Honeywell Inc. 1992 • Printed in U.S.A. • Form Number 69-0650B...
  • Page 6 Fig. 1—Montage et choix de l’emplacement. PERCER DES TROUS ET FIXER LA BRIDE AU MOYEN DES VIS FOURNIES CONDUIT DE FUMÉE DÉCOUPER UNE OUVERTURE DE 35 mm [1 3/8 po] DANS LE CONDUIT DE FUMÉE RESSERRER LA VIS DE BLOCAGE INSÉRER LA BILAME AU CENTRE DU CONDUIT DE FUMÉE SUR LE PASSAGE DES GAZ CHAUDS NE PAS FORCER LE COLLIER DE LA BRIDE DE MONTAGE AU-DELÀ...
  • Page 7 SYNCHRONISER LES CONTACTS DU Fig. 2—Schéma de raccordement du RA116A avec DÉTECTEUR PYROSTAT thermostat 24 V à trois fils. Les contacts du détecteur sont actionnés par un accouplement à friction au bout d’une tige directement L1 (SOUS TENSION) raccordée à l’élément actionné par la chaleur. Il arrive que l’accouplement ne soit plus synchronisé...
  • Page 8 à mazout ou du dispositif d’allumage afin d’éviter tout choc électrique. Département de la Régulation Résidentielle et Commerciale Pour la maîtrise de votre univers. Honeywell Limited-Limitée Honeywell Inc. 740 Ellesmere Road 1985 Douglas Drive North Scarborough (Ontario) M1P2V9...

Ce manuel est également adapté pour:

R116bR124aR124bR134aR168aR494a ... Afficher tout