Brief operating instruction
®
iTEMP
HART
KA193R/09/a3/01.10
51009803
®
DIN rail TMT112
de - Temperaturtransmitter (ab Seite 3)
en - Temperature transmitter (from page 11)
fr - Transmetteur de température
(à partir de page 19)

Publicité

Table des Matières
loading

Sommaire des Matières pour Endress+Hauser iTEMP HART TMT112

  • Page 1 Brief operating instruction ® ® iTEMP HART DIN rail TMT112 de - Temperaturtransmitter (ab Seite 3) en - Temperature transmitter (from page 11) fr - Transmetteur de température (à partir de page 19) KA193R/09/a3/01.10 51009803...
  • Page 3: Table Des Matières

    ® ® Temperaturtransmitter iTEMP HART DIN rail TMT112 Inhaltsverzeichnis 1 Sicherheitshinweise ........................3 2 Funktion............................4 3 Abmessungen ..........................4 4 Montage ............................5 5 Verdrahtung auf einen Blick ......................6 6 Bedienung ............................8 7 Zubehör............................10 8 Ergänzende Dokumentation ......................10 1 Sicherheitshin- Bestimmungsgemäße Verwendung weise...
  • Page 4: Funktion

    Montage und elektrische Installation des Geräts dürfen nur durch ausge- bildetes Fachpersonal unter besonderer Beachtung dieser Betriebsanlei- tung erfolgen. Der Temperaturtransmitter ist aufgrund seines Aufbaus nicht reparierbar. Für eine spätere Entsorgung beachten Sie bitte die örtlichen Vorschriften. Das Gerät darf nur von einem Netzteil mit energiebegrenztem Stromkreis nach IEC 61010-1 gespeist werden: "SELV or Class 2 circuit".
  • Page 5: Montage

    4 Montage Einbauhinweise Zulässige Umgebungstemperatur: -40 bis 85 °C (für Ex-Bereich siehe Ex-Zertifikate) Einbauort: Montage auf Hutschiene nach IEC 60715, z. B. im Schaltschrank Einbaulage: keine Einschränkungen...
  • Page 6: Verdrahtung Auf Einen Blick

    5 Verdrahtung Klemmenbelegung auf einen Blick...
  • Page 7 ® Anschluss HART -Kommunikation Gerätekonfigurator SFX100, Handbediengerät DXR375 oder Commubox FXA191 oder FXA195 in Verbindung mit PC und Endress+Hauser Bediensoftware (siehe »Bedienung« auf Seite 8). ® A = Anschluss HART -Kommunikation direkt am Temperaturtransmitter ® A* = Anschluss HART -Kommunikation am Speisegerät C = Der Messkreis muss eine Bürde von mindestens 250 Ω...
  • Page 8: Bedienung

    Anschluss Commubox: ® Stellen Sie hierzu den DIP-Schalter der Commubox auf ’HART ’! Potenzialausgleich Bei der Installation ist zu beachten: Schirmung der Ausgangsseite (Ausgangs- signal 4 bis 20 mA) und Schirmung der Sensoranschlussseite müssen das glei- che Potenzial haben! In Anlagen mit starken elektromagnetischen Feldern wird eine Schirmung aller Leitungen mit niederohmiger Anbindung an Erde empfohlen.
  • Page 9 Folgende Tabelle zeigt die Struktur der menügeführten Bedienung der PC- ® Konfigurationssoftware ReadWin 2000: Einstellbare Parameter Standardeinstellun- • Sensortyp • Anschlussart (2-, 3- oder 4-Leiterschaltung) • Messeinheit (°C/°F) • Messbereichsanfang (abhängig vom Sensor) • Messbereichsendwert (abhängig vom Sensor) • Koeffizient X0 bis X4 (bei Sensortyp Polynom RTD/TC) •...
  • Page 10: Zubehör

    7 Zubehör Schnittstellenkabel Commubox FXA191 (RS232) oder FXA195 (USB) Bestell-Code: FXA191-...; FXA195-... ® PC-Bediensoftware: FieldCare oder ReadWin 2000. Für Bestellungen kontaktieren Sie bitte Ihren Lieferanten. ® ReadWin 2000 kann kostenlos direkt vom Internet unter folgender Adresse geladen werden: www.produkte.endress.com/ReadWin Gerätekonfigurator Field Xpert SFX100 mit Wireless-Kommunikation über Bluetooth™-Modem.
  • Page 11 < ® ® Temperature transmitter iTEMP HART DIN rail TMT112 Table of contents 1 Safety notes ..........................11 2 Function ............................12 3 Dimensions........................... 12 4 Installation............................ 13 5 Wiring overview ........................... 14 6 Operation ............................. 16 7 Accessories ........................... 18 8 Supplementary documentation ......................
  • Page 12: Function

    Due to its construction, the transmitter cannot be repaired. When dispo- sing of the DIN rail transmitter, please take note of the local disposal regu- lations. The unit must only be powered by a power supply that operates using an IEC 61010-1 compliant energy limit circuit: "SELV or Class 2 circuit"...
  • Page 13: Installation

    4 Installation Installation conditions Ambient temperature: -40 to 85 °C (-40 to 185 °F), for Ex area see Ex certification Installation area: Installation on DIN rail according to IEC 60715, e. g. in control panel Installation angle: No limit...
  • Page 14: Wiring Overview

    5 Wiring Terminal layout overview...
  • Page 15 ® Connection HART communication Device configurator SFX100, hand operating module DXR375 or Commubox FXA191 or FXA195 in combination with PC and Endress+Hauser operating software (See “Operation” on page 16.). ® A = Connection HART communication directly to the transmitter ®...
  • Page 16: Operation

    Connection of Commubox: ® Set the Commubox DIP switch to ’HART ’! Potential levelling Please take note when installing the transmitter: The screen on the 4 to 20 mA signal output must have the same potential as the screen at the sensor connections! In plants with strong electromagnetic fields, screening of all cables with a low ohm connection to ground is recommended.
  • Page 17 The following table shows the structure of the PC configuration software ® ReadWin 2000 interactive menu operation: Presettable parameters Standard settings • Sensor type • Connection mode (2-, 3- or 4-wire connection) • Units (°C/°F) • Measurement range start (depends on sensor) •...
  • Page 18: Accessories

    7 Accessories Communication interfaces Commubox FXA191 (RS232) or FXA195 (USB): Order codes: FXA191-...; FXA195-... ® PC operating software: FieldCare or ReadWin 2000. Please contact your supplier when ordering. ® ReadWin 2000 can be downloaded free of charge from the Internet from the following address: www.products.endress.com/ReadWin Device configurator Field Xpert SFX100 with wireless communication via Bluetooth™-modem.
  • Page 19 ® ® Transmetteur de Température iTEMP HART DIN rail TMT112 Sommaire 1 Conseils de sécurité ........................19 2 Principe de fonctionnement ......................20 3 Dimensions........................... 20 4 Montage ............................21 5 Raccordement..........................22 6 Exploitation ..........................24 7 Accessoires ........................... 26 8 Documentation complémentaire....................
  • Page 20: Principe De Fonctionnement

    De par sa conception, le transmetteur n’est pas réparable. Pour la mise au rebut, tenir compte des normes en vigueur. L’appareil doit obligatoirement être alimenté par une alimentation stabilisée selon IEC 61010-1: "SELV or Class 2 circuit". 2 Principe de Acquisition et conversion électroniques des signaux d’entrée en un signal de fonctionnement sortie analogique pour la mesure de température industrielle.
  • Page 21: Montage

    4 Montage Conditions de montage Température ambiante : -40 à 85 °C (pour zone Ex, voir certificat Ex) Position de montage : Montage sur rail profilé selon IEC 60715, par ex. en armoire électrique Implantation : Pas de restriction...
  • Page 22: Raccordement

    5 Raccordement Aperçu...
  • Page 23 Raccordement HART® -communication Configurateur SFX100, terminal portable DXR375 ou Commubox FXA191 ou FXA195 en combinaison avec un PC et le logiciel Endress+Hauser (v. Chap. “Exploitation” ,p. 24). ® A = Raccordement communication HART directement au transmetteur de température ® A* = Raccordement communication HART à...
  • Page 24: Exploitation

    Raccordement Commubox: ® Mettre le commutateur DIP de Commubox sur ’HART ’! Compensation de potentiel Lors de l'installation, tenir compte des points suivants : le blindage côté sortie (signal de sortie 4 à 20 mA) et le blindage côté raccordement capteur doivent être au même potentiel ! Dans les installations comportant des champs magnétiques puissants, il est recommandé...
  • Page 25 Le tableau suivant représente la structure de la configuration pilotée par menu ® du logiciel PC ReadWin 2000 : Paramètres configurables Configuration standard • Type de capteur • Type de raccordement (2, 3 ou 4 fils) • Unité de mesure (°C/°F) •...
  • Page 26: Accessoires

    7 Accessoires Câble interface Commubox FXA191 (RS232) ou FXA195 (USB) Référence : FXA191-...; FXA195-... ® Le logiciel de configuration PC : FieldCare ou ReadWin 2000 Pour toute commande, veuillez contacter votre fournisseur. ® ReadWin 2000 peut être chargé gratuitement directement d’Internet à l’adresse suivante : www.products.endress.com/ReadWin Configurateur Field Xpert SFX100 avec communication sans fil via modem Bluetooth™.