1.4 Connection
Install a thermal-magnetic switch with RCCB (not supplied) on the wall. The wall-
•
mounted main switch must be 2-pole for G3130, G3131, G3134, G3136, G3138,
G3141 or 3-pole for G3137, G3139, G3142, G3149 with adjustable RCCB and
adjustable sensitivity I∆n.
Before the connection to the power, check that the voltage and frequency values
•
displayed on the technical plate are compatibles with the values of the power supply.
The appliance is supplied for a connection with values indicated on technical plate
•
(See pag. 15/48 for an example) and those values must be respected to allow the
correct use of the appliance.
Before doing any work, cut off the main electricity supply, connect the appliance to a
•
normalize plug available the operating voltage.
Connect the cable to an adequate electric socket. The appliance must be connected to
•
earth in accordance with current standard.
The earth wire must be longer than the others so that if the cable blocker should break,
•
it will disconnect after the tension wires.
At full working, the applied voltage must do not overreach the rated voltage ±10%.
•
The appliance must be connected to an equipotential system and the effectiveness of
•
this one is to check, according to normative in force. The connection screw is
identified by the
The cut-out switch or the plug must be near the appliance and easily to reach.
•
400
70
70
Cable
Electrical Input Fry-Top 1/2 Modul
symbol.
600
13/48
600
70
70
Cable
Electrical Input Fry-Top 1 Modul
mod. G10
600