Transient Response:
Temperature Coefficient:
Metering
(PL330QMT
only):
Meter Type:
Meter Resolution:
Meter Accuracy:
GENERAL
AC Input Voltage:
Power Consumption:
Operating Range:
Storage Range:
Environmental:
Weight:
Size:
Safety:
EMC:
< 20 µsec to within 50 mV of setting for 90% load change.
o
Typically < 100 ppm/
3·75 digit (4095 count) with 12·5mm (0·5") LEDs. Reading rate 4Hz.
10 mV and 10 mA
0·5% of reading + 1 digit.
Internally set for 110, 120, 220, 230 or 240VAC 50/60 Hz; operating range
±10% of setting. Installation Category II.
15V / 4A or 30V / 2A:
30V / 3A:
O
O
5
C to 40
C, 20% to 80% RH.
O
O
-20
C to +60
C.
Indoor use at altitudes up to 2000m, Pollution Degree 2.
15V / 4A or 30V / 2A:
30V / 3A:
Single
155 mm wide
All units 170mm high and 265mm deep, except PL330 versions 300mm
deep.
Complies with EN61010-1.
Complies with EN61326.
C.
Single
Dual
160VA
320VA
250VA
500VA
Single
Dual
5.0kg
9.5kg
6.0kg
12.0kg
Dual
Triple.
350 mm wide
425 mm wide
Triple
400VA
600VA
Triple
12.5kg
15.0kg
3