MAIN OUTPUT(S)
Output Range:
Output Voltage Setting:
Output Current Setting:
Output Mode:
Configuration Selection:
(QMD and QMT only)
Output Switch:
Output Terminals:
Sensing:
Output Impedance:
Constant Voltage:
Constant Current:
Output Protection:
Load & Line Regulation:
Ripple and Noise:
Transient Response:
Temperature Coefficient:
Meter Type:
Meter Resolution:
Meter Accuracy:
Current Meter Damping:
LOGIC OUTPUT (PL320QMT & PL330QMT)
Output Voltage Range:
Output Current:
Output Switch:
Output Terminals:
Over-Voltage Protection:
Output Protection:
Load & Line Regulation:
Ripple and Noise:
2
Nominally 0-32V, (PL320/330); 0-15.5V (PL154).
Nominally 0-2·1A (PL320); 0-3·1A (PL330); 0-4A (PL154).
By coarse and fine controls; resolution <5mV across the range.
By single logarithmic control.
Constant voltage or constant current modes with automatic cross-over.
Decimal points flash to indicate constant current mode.
Isolated, True parallel, Series, or Series Tracking via front panel switches.
Isolates the output and permits voltage and current limits to be set up before
connecting the load.
4mm terminals on 19mm (0·75") spacing.
Remote via 4mm terminals or direct via shorting links (provided).
<5 mΩ at 1kHz.
Typically 50 kΩ with voltage limit at maximum.
Up to maximum output voltage +20 Volts forward; diode clamped for reverse
voltages and up to 3A reverse current.
< 0·01% of maximum output for 90% load change or 10% line change.
Typically <1 mV rms.
< 20 µsec to within 50 mV of setting for 90% load change.
O
Typically < 100 ppm/
Dual 3·75 digit (4095 count) with 12·5mm (0·5") LEDs. Reading rate 4Hz.
10 mV and 1mA over the entire range.
Voltage 0·1% of reading + 1 digit, current 0·3% of reading + 1 digit.
~20 ms, switchable to 2 sec for averaging of rapidly varying loads.
4 to 6 Volts.
0·1 to 4 Amps (PL320QMT); 0·1 to 7 Amps (PL330QMT).
Electronic.
4mm terminals on 19mm (0·75") spacing.
Above 7 Volts.
Clamped by the over-voltage protection circuit for forward voltages over
7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages
and up to 3 Amps reverse current.
< 0·01% of maximum output for 90% load change or 10% line change.
Typically <1 mV rms.
C.
Specification