8
Problem
When I use my vacuum
cleaner I sometimes feel
electric shocks.
The vacuum cleaner
switched off, but I did not
press the on/off button.
The auto on/off feature
does not work.
The auto on/off icon
flashes.
Possible cause
Your vacuum cleaner builds
up static electricity. The lower
the air humidity, the more
static electricity the
appliance builds up.
The automatic on/off
function has been activated
because you did not move
the handgrip for 2 seconds.
You may have disabled the
feature.
The gyroscopic sensor does
not work.
Solution
Discharge the appliance by frequently
holding the tube against other metal
objects in the room (for example the
legs of a table or chair, a radiator etc.).
You can also raise the air humidity level
in the room.
As soon as you start moving the
handgrip again, the vacuum cleaner
switches on automatically.
Press and hold the on/off button on the
handgrip for 5 seconds to activate the
feature. The auto on/off icon lights up.
Please contact the Consumer Care
Center.