Operating Control Led; Application Example; Troubleshooting; Connection Example - Resol SV6 Manuel

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.4

Connection example

IP 20
SV6
Made in Germany
S1
S2
S3
S4
S5
out
out
out
out
out
1
2
3
4
5
Sensors
GND
1
2
3
4
5
6
2.5

Operating control LED

Green:
Everything OK
Red flashing:
Sensor fault
2.6

Application example

Outdoor
SV6 Sensor
temperature
distribution box
sensor
14
S6
S
VBus
out
in
6
SD
DeltaSol
IP 20
Made in Germany
R4|1 (1) A 30V
R1-R3|1 (1) A 240 V~
S6
S7
R4
7
8
9
FAP13
AM1
10
11
DeltaTherm
HC mini
®
3

Troubleshooting

T0,2A
Operating control LED flashes red.
100 ... 240 V~
50-60 Hz
T4A
N L
100 ... 240 V
Sensor fault. Check sensor.
50-60 Hz
®
SL
Operating control LED permanently off.
L
N
If the operating control LED is off, check the power supply of the device. Is it disconnected?
R3
R2
R1
L
no
N
N
N
N
The device is protected by a fuse. The
fuse holder (which also holds the spare
fuse) becomes accessible when the cover
is removed. To replace the fuse, pull the
fuse holder from the base.
fuse
yes
Check the supply line and reconnect it.