The DREAM control unit can be used to control 1 motor with power not exceeding 500W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically separated, or adequately insulated by an
additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f) Normally Closed inputs which are not in use should be short-circuited.
Terminal no.
Function
1-2
Power Supply
3-4-5
Motor
3-5
Capacitor
6-7
24 Vac
8-9
Step-by-Step
PHOT/SAFETY
10-11
EDGE
12-13
TIMER/2nd ch.
14-15
Antenna
MD1
RADIO
DIP 1
"CVAR" – Fixed code transmitters are enabled or disabled.
On: Only variable-code transmitters are enabled (14 codes maximum).
Off: Both variable code transmitters and fixed code transmitters are enabled (14 codes
maximum).
DIP 2
See paragraph "Learning of stroke"
DIP 3
"PHOT/SAFETY EDGE" – Selects the operating mode of input 10-11.
On: When the contact is opened in the closing phase the gate/door stops (STOP).
The control following the stop will always be an OPEN control signal.
Off: The opening of the contact causes the movement reversion until the gate is totally opened.
At this point, the counting of the remaining operating time and of the possible automatic closure
starts. At end of counting, the control unit starts a new closing operation.
6
DREAM Control Unit
GENERAL WARNINGS
INPUTS/OUTPUTS
Description
DREAM: Input, 230Vac 50Hz (1-Phase/2-Neutral)
Model DREAM115: Input 115vac 60Hz (1-Phase/2-Neutral)
Connection to motor (3-marcia/4-Com/5-marcia)
Connection to capacitor
Output, power supply of accessories, 24Vac/100 mA max.
Input, step-by-step push button open>stop>close>stop.
N.O. contact
Input, photocell or safety edge.
It is activated in the closing phase only.
It is used as photocell input:
Jumper J4 Open. Dip-Switch 3 OFF.
Used as input for safety edge:
Safety edge of the resistive type: Jumper "J4" closed. Dip-Switch
3 OFF.
Safety edge of the mechanical type: Jumper "J4" open. Dip-
Switch 3 OFF.
Output (N.O. contact). It can be set for second radio channel or
timed. See description of DIP 4.
Connection of antenna with built-in radio receiver module
(14-signal/15-display).
Built-in two-channel radio receiver. See DIP 1
FUNCTIONS OF DIP-SWITCHES