Mains
230V~ 50/60Hz
400V~ 50/60Hz
( * ) calculated with the simultaneous factor following standard EN 60 335-2-6
Important
It is forbidden to extent or to shorten the liaison wires areas of the cooking zones ( 5,6,7,8;)
Only the control panel (C) may be extended (Order our only lengthens ref A10506/0).
Monophase 230V~1P+N:
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminate "earth", the neutral N to terminal 3 or 4, the Phase L to one of
the terminals 1 or 2.
Biphase 400V~2P+N:
Put a bridge between terminal 3 and 4.
Attach the earth to the terminate "earth", the neutral N to terminal 3 or 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between 3 and 4.
16
Protection calibre
25 A *
16 A *