CARACTERISTIQUES TECHNIQUES
UNITE CENTRALE ....................................................................................................................
UNITE CENTRALE
UNITE CENTRALE
UNITE CENTRALE
UNITE CENTRALE
.................................................................................................................... Art. 0144
....................................................................................................................
....................................................................................................................
....................................................................................................................
- TENSION D'ALIMENTATION NOMINALE ....................................................................................................................................................... 12 Vcc
- TENSION DE SERVICE .......................................................................................................................................................................................... 9/15 Vcc
- CONSOMMATION DE COURANT 12 V
(SYSTEME DESACTIVE) (sans sirène) .................................................................................................................................................................. < 7 mA
- CONSOMMATION DE COURANT 12 V TENSION CONTINUE
(SYSTEME ACTIVE) (sans sirène) .......................................................................................................................................................................... < 8 mA
- SYSTEME EN ALARME (avec sirène) .................................................................................................................................................................... < 1,3 A
- TEMPERATURE DE FONCTIONNEMENT .................................................................................................................................................. -30/+85°C
- DUREE RETARD INHIBITION ..................................................................................................................................................................... 40 secondes
- DUREES ENTRE DEUX ALARMES CONSECUTIVES ............................................................................................................................... 5 secondes
- INTENSITE DE COURANT MAX RELAIS INDICATEURS DE DIRECTION ............................................................................................. 5+5 A
- DUREE MAX CYCLE ALARME .................................................................................................................................................................... 30 secondes
- DIMENSIONS ......................................................................................................................................................................................... 110 x 85 x 35 mm
- POIDS ............................................................................................................................................................................................................................... 170 g
TOUTES LES CENTRALES SONT CONFORMES A LA NORME ISO DP 7637/1 (POUR LE TRANSITOIRE ELECTRIQUE)
ET A LA NORME IEC 68-2-30 (POUR LES ESSAIS CLIMATIQUES).
SIRENE
SIRENE
.......................................................................................................................................
.......................................................................................................................................
SIRENE .......................................................................................................................................
SIRENE
SIRENE
....................................................................................................................................... Art. 5370
.......................................................................................................................................
- TENSION D'ALIMENTATION NOMINALE ....................................................................................................................................................... 12 Vcc
- TENSION DE SERVICE .......................................................................................................................................................................................... 9/16 Vcc
- CONSOMMATION DE COURANT 12 V
TENSION CONTINUE (ALARME DESACTIVEE) ............................................................................................................................................ < 2 mA
- CONSOMMATION DE COURANT 12 V
TENSION CONTINUE (ALARME ACTIVEE) ................................................................................................................................................. < 1,3 mA
- TEMPERATURE DE FONCTIONNEMENT .................................................................................................................................................. -30/+85°C
- PUISSANCE SONORE ................................................................................................................................................................................ 115 dB @ 1 m
- CYCLES MAX POUR BATTERIE AUXILIAIRE .............................................................................................................................................................. 9
- DUREE CYCLES ALARME POUR BATTERIE AUXILIAIRE .................................................................................................................. 28 secondes
- PAUSE ENTRE ALARMES CONTINUES POUR AUTOALIMENTATION .......................................................................................... 4 secondes
- AUTONOMIE BATTERIE AUXILIAIRE ................................................................................................................................................................. > 5mn
- DIMENSIONS ........................................................................................................................................................................................... 79 x 90 x 65 mm
- POIDS ............................................................................................................................................................................................................................... 360 g
TOUTES LES SIRENES SONT CONFORMES A LA NORME ISO DP 7637/1 (POUR LE TRANSITOIRE ELECTRIQUE) ET
A LA NORME IEC 68-2-30 (POUR LES ESSAIS CLIMATIQUES).
ANOMALIES ET SOLUTIONS
ANOMALIE
Quand vous actionnez la telecommande
d'origine de la voiture, les portières
s'ouvrent et se ferment mais le système
de protection ne s'active/désactive pas.
Le système peut être activé/désactivé,
mais les indicateurs de direction ne
fonctionnent pas.
La sirène ne sonne pas quand on ouvre
les portières.
Page - 48
CAUSE
• Le boîtier n'est pas parfaitement
alimenté.
• Le boîtier n'a pas effectué l'auto-
apprentissage de la polarité des
commandes
de
verrouillage/
déverrouillage.
• Les fils VIOLET, ORANGE, VIOLET-
BLANC et ORANGE-BLANC ne sont
pas branchés aux points prévus.
• Le fusible du câblage a sauté.
• Le fil JAUNE-ROUGE (JO2/1) n'a pas été
relié au +30.
• La centrale est désactivée.
• Les fils BLEU, BLEU-ROSE ne sont pas
bien reliés aux boutons des portières-
capot-coffre.
Cobra / Art. 0144 - Notice de Montage
SOLUTION
• Contrôlez qu'entre les fils de couleur
ROUGE et NOIRE dans le connecteur
du boîtier (pos. JO2/15 et JO2/14), il y a
min. 9 V et max. 15 V.
• Déconnectez le boîtier, attendez
quelques secondes puis reconnectez.
• Déconnectez le boîtier et contrôlez
l'installation des fils.
• Recherchez la mouvaise connection et
changez le fusible.
• Assurez-vous que le fil JAUNE-ROUGE
(JO2/1) a bien été mis en place.
• Activer le système au moyen de la
télécommande d'origine (T.I.R.).
• Assurez-vous que les fils BLEU, BLEU-
ROSE ont bien été mis en place.
Art. 0144
Art. 0144
Art. 0144
Art. 0144
Art. 5370
Art. 5370
Art. 5370
Art. 5370
Section - 4