INSTALLING & CLEANING CARTRIDGE FILTER
1
2
INSTALLING CARTRIDGE FILTER
1. Verify that the power cord is disconnected from the outlet (Fig. 1).
2. Remove power head and place in upside-down position.
3. Install the cartridge filter over the filter cage making sure the cage is completely covered
(Fig. 2 & 3).
4. Place the filter retainer on the top of the cartridge filter over the raised lip and tighten down by
turning the retainer clockwise; do not over-tighten (Fig. 4 & 5).
5. Place the power head back onto the collection tank.
REMOVING & CLEANING CARTRIDGE FILTER
1. Unlock and remove the filter retainer by turning retainer handle counterclockwise.
2. With the removed power head in an upside-down position, carefully remove the cartridge filter
from the filter cage (Fig. 6).
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning should not be done
indoors in living areas. For optimal performance, a new filter is recommended.
4. Install cleaned or new filters as above in steps 2-4 of Installing Cartridge Filter.
5. Allow the wet filter to air dry for 24 hours before installing onto the filter cage.
3
4
13
5
6