Operation - Makita UB400MP Manuel D'instructions

Masquer les pouces Voir aussi pour UB400MP:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To remove the pipe, turn the lever toward the
attachment and pull the pipe out while pressing
down the release button.
Fig.12
► 1. Release button 2. Lever 3. Pipe
Installing the flat nozzle or
extension nozzle
Optional accessory
1.
Remove the front nozzle by turning it as
shown in the figure.
► 1. Front nozzle
2.
Attach the adapter pipe to the attachment,
and then turn it to lock it into place.
1
► 1. Adapter pipe 2. Attachment
1
2
1
3.
Attach the flat nozzle or extension nozzle
to the adapter pipe, and then turn it to lock it into
place.
1
3
2
► 1. Flat nozzle 2. Extension nozzle 3. Adapter
pipe
NOTICE:
of the flat nozzle or extension nozzle are
not available. Be sure to use the grooves
shown in the figure to attach the flat nozzle
or extension nozzle.

OPERATION

WARNING:
precautions in the chapter "SAFETY
WARNINGS" and the instruction manual of
the power unit.
WARNING:
and shoulder harness to your comfortable
position before operating.
2
CAUTION:
the ground while it is switched on. Sand or
dust may enter from suction inlet and cause a
malfunction or personal injury.
Hold the machine firmly with both hands and per-
form the blowing operation by moving it around
slowly. When blowing around building, big stone
or vehicle, direct the nozzle away from them.
When performing an operation in a corner, start
from the corner and then move to wide area.
Adjust the air speed with the switch trigger or
throttle lever of the power unit according to the
environment or conditions of your usage.
9
ENGLISH
The grooves on the deep side
Follow the warnings and
Adjust the hanger position
Do not place the machine on
3

Publicité

Table des Matières
loading

Table des Matières