OperatiOn and MaintenanCe

the ultraKlear
uV clarifier eliminates single-celled algae
®
commonly referred to as green water. for most ponds
the process should take approximately 1 week, however
significant algae blooms may take 2-3 weeks to clear.
• Bulb life – for effective clarification the uV bulb should
be replaced after 12 months of continuous use. NOTE:
Even though the UV bulb still emits light it may have lost
tO aCCeSS the qUartz tUbe
1. always unplug both the pump and the ultraKlear
uV clarifier before servicing.
2. release the latch tab by pulling/pushing it towards the
ballast about ¼".
3. rotate the ballast counter-clockwise about ½" to release
it from the locked position and carefully slide out the
ballast with quartz tube attached.
4. the quartz sleeve can now be accessed for cleaning
or replacement.
www.aquascapeinc.com |
®
CAN 1-866-766-3426 |
its effectiveness at clarifying if the recommended operating
time has been exceeded.
• Cleaning/Replacing the quartz tube and UV bulb –
a dirty quartz tube will reduce the effectiveness of the uV
bulb. Debris and mineral deposits can be cleaned using a
mild acid like white vinegar or a non-abrasive calcium, lime
or rust remover with a soft bristled brush or sponge.
US 1-866-877-6637