I N S T R U C T I O N S
ULTRA
WATER PUMP
Submersible
fountain, waterfall
and filter pump
For Models:
400 (Item #91005)
550 (Item #91006)
800 (Item #91007)
1100 (Item #91008)
1500 (Item #91009)
2000 (Item #91010)
Available in flow rates
from 400 to 2000 GPH.
91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd 1
Document Created by: Sikich Marketing & Public Relations
Document Creator Contact Information:
Sikich Marketing & Public Relations
1415 W. Diehl Rd., Suite 400
Naperville, IL 60563
p 630.717.7515
f 630.566.8401
&
Ultra
400/550/800/1100
Document Designer:
Rick Byers
Designer E-Mail:
rbyers@sikich.com
Sikich Job Number:
140911276
Number of Colors
1/1
Number of Pages
16
Flat Size
17" x 11"
(W x H)
M A I N T E N A N C E
Ultra
1500/2000
www.aquascapeinc.com
Client
Client Contact
Client Contact E-Mail
Client P.O. Number
Client Job Description:
Folded Size
(W x H x D)
3
10/3/14 3:12 PM
Aquascape, Inc.
Flavio Ramirez
framirez@aquascapeinc.com
140178
91054 Ultra Pump Instructions 10-14
8.5" x 11"

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour AquaScape Ultra 400

  • Page 1 91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd 1 10/3/14 3:12 PM Document Created by: Sikich Marketing & Public Relations Document Designer: Rick Byers Client Aquascape, Inc. Document Creator Contact Information: Designer E-Mail: rbyers@sikich.com Client Contact Flavio Ramirez Sikich Marketing &...
  • Page 2: Table Des Matières

    ULTRA ™ WATER PUMP Thank you for choosing the Aquascape Ultra pump. At Aquascape, our goal ™ is to supply our customers with the best valued products in water gardening. We hope you enjoy your purchase and thank you for choosing Aquascape.
  • Page 3: Introduction

    If you currently own an Ultra Pump and want to add a new dimension ™ to your pond with the addition of a fountain, Aquascape makes it simple with the addition of the new Ultra Pump ™ Fountain Head Kit. Kit comes...
  • Page 4: Safety Information

    DO NOT OPERATE DRY! IMPORTANT: Aquascape, Inc. is not responsible for losses, injury, or death resulting from a failure • Use only in fully assembled state, paying particular...
  • Page 5 Ultra ™ Pump Specs Model Number 1100 1500 2000 Item Number #91005 #91006 #91007 #91008 #91009 #91010 Maximum Flow Rate 370 GPH 528 GPH 793 GPH 1110 GPH 1480 GPH 1982 GPH Maximum Head Height 7.55 ft 7.87 ft 9.19 ft 12.14 ft 16.4 ft 20.01 ft...
  • Page 6: Operation And Maintenance

    • The convenient 3-Way fitting on the filter before attaching the tubing/hose. Once Diverter Fitting provides the fitting is in place, attach the tubing/hose onto the fitting you with the ability to with a twisting motion pushing it into place. connect and adjust the •...
  • Page 7 Replacing the impeller is extremely easy. Replacement Impeller Kits are available through your local Aquascape dealer. ® 1a. Note the orientation of parts in the photo below.
  • Page 8: Troubleshooting

    – The pump is not receiving the correct voltage. For more information about our company or products, please visit our website at www.aquascapeinc.com or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426 91054.11276 ©2014 Aquascape, Inc. • All Worldwide Rights Reserved ☎ ☎ US 1-866-877-6637 | CAN 1-866-766-3426 | www.aquascapeinc.com...
  • Page 9 91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd 9 10/3/14 3:12 PM Document Created by: Sikich Graphic Design & Marketing Services Document Designer: Rick Byers Client Aquascape, Inc. Document Creator Contact Information: Designer E-Mail: rbyers@sikich.com Client Contact Scott Rhodes Sikich Graphic Design &...
  • Page 10 être vérifiées afin de s’assurer de leur bon fonctionnement avant de les retourner en tant qu’unité défectueuse. Aquascape inc. ou ses filiales n’assumeront aucune responsabilité en cas de perte ou de dégâts de n’importe quelle nature, provenant ou résultant de l’utilisation du produit, défectueux ou non.
  • Page 11: Introduction

    à votre plan d’eau en y installant une fontaine, Aquascape vous simplifie la tâche grâce au nouvel ensemble de têtes de fontaine pour la pompe Ultra . Cet ensemble inclut trois têtes de fontaine : une cloche d’eau, un jet moussant et une fontaine marguerite...
  • Page 12: Renseignements De Sécurité

    PAS FONCTIONNER LA POMPE À SEC! • Utilisez seulement lorsque la pompe est entièrement IMPORTANT: Aquascape inc. n’est nullement assemblée, en prêtant une attention particulière pour que responsable des pertes, blessures ou décès la grille de filtration et l’éponge soient fixées à la pompe.
  • Page 13 Caractéristiques techniques des pompes Ultra Numéro de modèle 1100 1500 2000 Numéro de l’article 91005 91006 91007 91008 91009 91010 Débit maximal 1 400,5 L/h 1 998,5 L/h 3001,5 L/h 4163,5 L/h 5601,8 L/h 7501,9 L/h Hauteur maximale 2,30 m 2,40 m 2,80 m 3,70 m...
  • Page 14: Fonctionnement Et Entretien

    • Le raccord pratique de conseillons de placer le raccord sur le filtre avant de la vanne directionnelle à raccorder le tuyau . Une fois que le montage est en place, trois voies vous permet fixez le tuyau sur le raccord avec un mouvement de torsion de connecter et d’ajuster poussant en place.
  • Page 15 Aquascape de tour dans le sens inverse des aiguilles d’une montre 1a. Assurez-vous que l’arbre de la turbine siège dans la au-delà...
  • Page 16: Diagnostic Des Pannes

    Pour plus de renseignements au sujet de notre société ou de nos produits, veuillez visiter notre site Web au www.aquascapeinc.com ou téléphonez sans frais au 1 866 766 3426, au Canada, ou au 1 866 877 6637, aux États-Unis. 91054.11276 ©2014 Aquascape, Inc. • Tous droits réservés mondialement ☎ ☎...