Ultra
Pump
Installation Instructions
PaCkage InClUdes:
One of the following:
• 200, 350, 500, 750,
1000 or 1500 gph
Ultra Pump
• Instructions for Use
Features
• Fully submersible and energy efficient
• Powers ornamental fountains and statuary
Congratulations on your purchase of
this Ultra
submersible pump.
You will find this pump ideal for use in water gardens,
ponds and to power small ornamental fountains and
statuaries. These pumps are very energy efficient, using
50% less power than conventional pumps. They are
Installation
1) If a fountain is not required, connect hose
directly to the outlet adapter and secure with
hose clamp.
2) Place pump in pond. If fountain is in use, ensure
fountain head is above water level.
3) Plug pump cord into grounded outlet. Ensure
cable is protected — keep away from children
and garden hazards. For proper operation, ensure
that inlet is filled with water.
Pump Performance
Model
gph full open
Cord length
200 gph
200
12'
350 gph
350
12'
500 gph
500
12'
750 gph
750
25'
1000 gph
1000
25'
1500 gph
1500
25'
Troubleshooting
Reduced Flow:
• Check pump and impeller for any blockages. It may
be necessary to take the impeller and prefilter out
and clean them.
• Check pipe and plumbing for any kinks or blockages.
Item #'s 11000.11799.12100
13500.15100.17500.042006
11000 Ultra Submersible Pump Ins1 1
• Prefilter system built in prevents clogging
• Fish safe, environmentally friendly materials
designed to be operated fully submerged and can be
operated in line. Made with environmentally friendly
materials, they are fish safe. The pumps are fitted with
a pre-filter system to prevent clogging and wear on the
impeller. The motors are epoxy encapsulated, not oil filled
and are
CSA
approved.
C
US
Maintenance
1) Remove pump from electrical supply.
2) Wash pre-filter in fresh, running water. Never use
chemical detergents when cleaning. Handle filter
sponge material carefully.
3) Remove impeller, inspect and clean in running
water; replace if worn or damaged.
4) Reassemble pump; reconnect to electrical supply.
MaInTenanCe nOTes:
• Check cord periodically for sharp bends and correct.
• If pump is taken out of service, flush with fresh water and
allow to drain dry prior to storage.
gph @ 2'
gph @ 5'
Max Head
Thread size
160
-
4'
3/8"
320
200
6'
1/2"
440
310
8'
1/2"
710
580
10'
3/4"
940
800
14'
3/4"
1400
1000
14'
3/4"
Pump is not pumping:
• Make sure nothing is blocking the impeller. It may be
necessary to clean pump.
©2006 aquascape, Inc. • all Worldwide Rights Reserved
saFeTY COnsIdeRaTIOns
• This product must be installed on an electrical circuit protected by a Ground Fault Circuit
Interrupter (GFCI). Refer to your electric supply dealer for details.
• If you have any questions or doubts about this product, consult a qualified electrician.
• Do not lift the pump by the power cord — it is not designed for portable use.
• Always disconnect from electrical supply before attempting to service or perform
maintenance procedures.
RePlaCeMenT PaRTs
To order replacement parts, contact your local Aquascape™ retailer.
Replacement Part
Item #
200 gph Impeller
20351
350 gph Impeller
20352
500 gph Impeller
20353
750 gph Impeller
20354
1000 gph Impeller
20355
1500 gph Impeller
20356
Screen
99610
350-500 gph Repl. Foam Pre-Filter
99319
200 gph Repl. Foam Pre-Filter
27501
750-1500 gph Repl. Foam Pre-Filter
96001
This Aquascape, Inc. product is warranted against
defects in materials or workmanship for a period
of 36 months starting at the date of purchase by
the customer. Registration must be on file with
Aquascape, Inc. This is the only warranty applicable
for this product. Our obligation under this warranty
is limited to the repair or replacement of the product
if it fails to operate. Neither Aquascape, Inc. nor the
seller is liable for injury, loss or damage related to
the use of the product. However, this limitation is not
applicable in some states.
The warranty is void if any of the following is found:
1) Abuse of product by the customer.
2) Product connected to an electrical supply other
3) Power cord cut to a length of less than three feet.
4) For pumps: (a) sealed motor housing opened;
Impeller Cover
Screen
Watts
12
Pre-Filter
35
40
45
50
90
1
1
YEAR
YEAR
WARRANTY
WARRANTY
1
1
GARANTIE
GARANTIE
DE 1 AN
DE 1 AN
2
2
YEAR
YEAR
Replacement Part
Item#
Divert Valve
20000
Maxi Waterbell Fountain Head
21000
Maxi Waterlily Fountain Head
22000
WARRANTY
WARRANTY
Foam Jet Fountain Head
23000
Maxi Daisy Fountain Head
24000
2
2
Threaded Adapter
99602
(converts metric to US)
GARANTIE
GARANTIE
Oasis Collection
20100
DE 2 ANS
DE 2 ANS
(compatible w/200gph and statuary pumps only)
750-1500 gph O-Ring
99635
200-500 gph O-Ring
99611
3
3
YEAR
YEAR
WARRANTY
WARRANTY
3
3
GARANTIE
GARANTIE
DE 3 ANS
DE 3 ANS
than specified.
(b) pump operated dry, with fluid supply shut
off and (c) pump used to circulate material other
than fresh water, light oils or other mild liquids at
approximately room temperature.
Rubber Case
Adapter
(on 200gph only)
Motor
Impeller
O-Ring
Made in China for
Aquascape, Inc.
St. Charles, IL 60174 • Brampton,ON, L6T 5V7
www.aquascapeinc.com
IDD 06044481-ADI B060201
5/31/06 11:13:47 AM

Publicité

loading

Sommaire des Matières pour AquaScape Ultra 200 gph

  • Page 1 Neither Aquascape, Inc. nor the 50% less power than conventional pumps. They are seller is liable for injury, loss or damage related to the use of the product.
  • Page 2 • Il faut toujours débrancher l’alimentation électrique avant de procéder à l’entretien de la pompe. PIÈCes de ReCHange Directives d’installation WARRANTY WARRANTY Pour commander des pièces de rechange, veuillez contacter votre détaillant Aquascape l’eMBallage COMPRend : Pièce de rechange no. article Pièce de rechange no.

Ce manuel est également adapté pour:

Ultra 350 gphUltra 500 gphUltra 750 gphUltra 1000 gphUltra 1500 gph