Mi-T-M Corporation Elite Serie Manuel De L'opérateur page 19

Masquer les pouces Voir aussi pour Elite Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SYMPTOM
Electrical
Piping
Propane and Natural Gas Portable Heaters Manual
TROUBLESHOOTING
PROBABLE CAUSE
Faulty igniter/flame sensor
Ignition board
Thermostat
All components
All pipe fittings
REMEDY
Ensure connections are secure. Re-
place igniter / flame sensor if neces-
sary.
Check ground wire for proper connec-
tion.
Visually check the Power Supply Indi-
cator (see sticker on heater)
Green light - Meets Power Req.
Solid Red Light - Reverse Polarity.
Flashing Red Light- Ground or Neutral
Missing.
Ensure thermostat is calling for heat.
NOTE: If the thermostat is not calling
for heat, the appliance will not operate.
Before replacing any component,
all connections must be checked to
ensure electrical circuit is complete.
(Use volt meter and enclosed wiring
diagram.).
When loosened, tightened or replaced,
the complete fitting should be removed
and approved pipe dope applied to all
male threads before reconnection.
After a heater is serviced, the valve
train should be checked for leaks with
a soap and water solution or approved
leak detector solution.
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-0355-0mdhMh-0355-cmdh

Table des Matières