ELECTRIC CONNECTION

The housing of the display unit is suitable for wall mounting and is connected to
the 230 V mains supply. Under normal circumstances, the display unit must be operated with
the housing cover closed.
It is installed and started up by a qualified technician while the unit is open.
Observe the safety precautions and the assembly and operating instructions of
connected devices.
Electrical power connection of the display unit type LWG 2000
Electrical power connection of the display unit type LWG 2005
part no. 15 073 96
Danger to life due to electric shock!
Electric shock from touching live parts.
Before opening the housing, ensure that the equipment is free of
all voltage.
Only place under tension after ending all work.
A6
Nipple for cable lead-through 3x
A
Terminal for "power supply"
B
Terminal for additional "alarm"
C
Terminal for probe 4 and 5
Via terminal "Power"
AC voltage 230 V/ 50 Hz
Use only a fixed connection, not a pug
or switch.
Insert the cable through the nipple.
Connect the cable according to the
terminal block designation.
A6
Nipple for cable lead-through 3x
A
Terminal for "power supply"
B
Terminal for additional "alarm"
C
Terminal for probe 4 and 5
Via terminal "Power"
AC voltage 230 V/ 50 Hz
Use only a fixed connection, not a pug
or switch.
Insert the cable through the nipple.
Connect the cable according to the
terminal block designation.
Probe
.
.