Dig a rectangular shaped excavation,
by the sensitive element
gate installation.
Warning: Greater depths will lead directly to a loss in sensitivity.
rotect the sensitive element with a special plastic sheath
• P
underground
• Connect the loop to the special interwound cable (max. length 5 m) using a watertight shunt box "F". The
use of a shunt box will make later maintenance interventions easier. The interwound cable connection
should be as short as possible in order to optimise the operation of the system.
Gate
Sensitive element
not deeper than 100 mm,
"B" fig. 1. The excavation must be at least 1 meter away from the automatic
in the area which is to be controlled
"C"
14
1 m min
which is suitable for laying