NOTE: Switch administrators are strongly advised to maintain Dell Networking switches on the latest version of the Dell Networking Operating System (DNOS). Dell Networking continually improves the features and functions of DNOS based on feedback from you, the customer. For critical infrastructure, pre-staging of the new release into a non-critical portion of the network is recommended to verify network configuration and operation with the new DNOS version.
220V/50Hz Main PSU 2.14A 459.37W 240V/50Hz Main PSU 1.97A 459.06W Ventilation System One fan cools the N1108T-ON/N1108P-ON switches, and two fans cool the N1024T-ON/N1024P-ON/N1048T-ON/N1048P-ON switches. The fans are not field replaceable. The N1108EP-ON is a fanless switch. Getting Started Guide...
CAUTION: When mounting multiple switches into a rack, mount the switches from the bottom up. 1 Secure the N1108T-ON/N1108P-ON switch in the Dell Tandem Tray Kit as shown in Figure 1-1. Figure 1-1. Dell Tandem Tray Kit 2 Insert the switch into the 48.26 cm (19 inch) rack, ensuring that the rack mounting holes on the kit line up to the mounting holes in the rack.
Mounting an N1108T-ON/N1108P-ON/N1108EP-ON on a Two-Post Rack Using Large L-brackets NOTE: The AC power connector is on the rear panel of the N1108T-ON/N1108P-ON switches. The DC power connector for the N1108EP-ON is at the center of the rear panel. NOTE: The N1108EP-ON switch uses an external power adaptor.
4 Insert the switch and rail assembly into the rack from the front of the rack. Make sure that the rack-mounting holes on the switch line up to the mounting holes on the rack. 5 Secure the switch to the rack with the rack screws. Fasten the lower pair of screws before the upper pair of screws.
Page 12
Figure 1-4. Inserting Mounting Brackets 4 Repeat the process for the wall-mounting bracket on the other side of the switch. 5 Place the switch on the wall in the location where the switch is being installed. 6 Mark the locations on the wall where the screws to hold the switch must be prepared.
Page 13
Figure 1-5. Mounting on a Wall Getting Started Guide...
N1124T-ON/N1124P-ON/N1148T-ON/ N1148P-ON Installation Rack Mounting an N1124T-ON/N1124P-ON/ N1148T-ON/ N1148P-ON Switch WARNING: Safety and Regulatory Information Read the safety information in the as well as the safety information for other switches that connect to or support the switch. The AC power connector is on the rear panel of the switch. Installing in a Rack WARNING: Do not use rack mounting kits to suspend the switch from under a...
Installing as a Free-standing Switch NOTE: Dell strongly recommends mounting the switch in a rack. Install the switch on a flat surface if you are not installing it in a rack. The surface must be able to support the weight of the switch and the switch cables.
Starting and Configuring the N1100-ON Series Switch The following flow chart provides an overview of the steps you use to perform the initial configuration after the switch is unpacked and mounted. Installation and Configuration Flow Chart Figure 1-7. Getting Started Guide...
Terminal keys (not Microsoft Windows keys). 3 Connect the USB type B connector on the cable directly to the switch console port. The Dell Networking console port is located on the right side of the front panel and is labeled with a |O|O| symbol.
The N1108T-ON and N1108P-ON models have one internal power supply. The power receptacle is on the rear panel. N1108EP-ON uses an external DC power adaptor.
Booting the N1100-ON Series Switch When the power is turned on with the local terminal already connected, the switch goes through a power-on self-test (POST). POST runs every time the switch is initialized and checks hardware components to determine if the switch is fully operational before completely booting.
• The Dell Networking switch booted successfully. • The console connection was established, and the Dell Easy Setup Wizard prompt appears on the screen of a PC running terminal emulation software. The initial switch configuration is performed through the console port. After...
NOTE: If you do not run the Dell Easy Setup Wizard or do not respond to the initial Easy Setup Wizard prompt within 60 seconds, the switch enters CLI mode. You must reset the switch with an empty startup configuration in order to rerun the Dell Easy Setup Wizard.
Example Session This section describes a Dell Easy Setup Wizard session. The following values are used by the example session: • The SNMP community string to be used is public. • The network management system (NMS) IP address is 10.1.2.100.
Dell Easy Setup Wizard Console Example The following example contains the sequence of prompts and responses associated with running an example Dell Easy Setup Wizard session, using the input values listed earlier. After the switch completes the POST and is booted, the following dialog appears: Unit 1 - Waiting to select management unit)>...
Page 24
Dell. You further agree to allow Dell to transmit and store the Collected Data from SupportAssist in accordance with these terms. You agree that the provision of SupportAssist may involve international transfers of data from you to Dell and/or to Dell's affiliates, subcontractors or business partners.
Page 25
The wizard automatically assigns the highest access level [Privilege Level 15] to this account. You can use Dell Network Manager or other management interfaces to change this setting, and to add additional management system information later.
Page 26
Step 2: Now we need to set up your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface. You may set up other accounts and change privilege levels later. For more information on setting up user accounts and changing privilege levels, see the user documentation.
If the information is incorrect, enter (N) to discard the configuration and restart the wizard: [Y/N] y Thank you for using the Dell Easy Setup Wizard. You will now enter CLI mode. Applying Interface configuration, please wait...
Page 28
VLANs and spanning tree protocol. Use the Web-based management interface or the CLI to configure the features your network requires. For information about how to configure the switch features, refer to the User Configuration Guide or CLI Reference Guide available on the support site: dell.com/support. Getting Started Guide...
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Dell EMC is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment.
Page 30
Figure 1-8. Canadian department of communication statement Safety standards and compliance agency certifications • IEC 62368-1, 2nd Edition • CUS UL 60950-1, 2nd Edition • Meets or exceeds Hi Pot and Ground Continuity testing per UL 60950-1. • AS/NZS 60950 •...
Page 31
Dell EMC encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell EMC offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa Fe Delegación Álvaro Obregón, Ciudad de México. C.P. 01219 R.F.C: DME9204099R6 Supply voltage: Dell Networking N1100-ON Series: 100V–240 VAC Frequency: Dell Networking N1100-ON Series: 50–60 Hz Maximum steady state Dell Networking N1100-ON Series: current consumption: •...
Page 34
Dell Networking N1108T-ON/N1108P-ON/ N1108EP-ON/N1124T-ON/ N1124P-ON/N1148T-ON/ N1148P-ON Guide de mise en route Modèles réglementaires : E17W et E18W...
Page 36
Installation des commutateurs N1108T-ON/N1108P-ON/N1108EP-ON . . . Montage d’un commutateur N1108T-ON/N1108P-ON à l’aide d’un plateau tandem Dell ... . Montage d’un commutateur N1108T-ON/N1108P-ON/ N1108EP-ON sur un rack à deux montants à l’aide de grands supports en L .
Page 37
Exemple de session ....Exemple de la console Assistant Dell d’installation facile ....
REMARQUE: Il est fortement recommandé aux administrateurs des commutateurs de veiller à ce que les commutateurs Dell Networking soient toujours équipés de la version la plus récente de DNOS Dell Networking, le système d’exploitation Dell Networking. Dell Networking améliore en permanence les caractéristiques et les fonctions de DNOS à...
Page 39
Tableau1-1. Consommation électrique des commutateurs PoE Série N1100-ON Modèle Tension Configuration du bloc Consommation Puissance d’entrée d’alimentation maximale de constante courant maximale constant (A) (en W) N1108P-ON 100 V/60 Hz PSU principal 0,95 A 88,64 W 110 V/60 Hz PSU principal 0,87 A 88,43 W 120 V/60 Hz...
Système de ventilation Un seul ventilateur refroidit les commutateurs N1108T-ON/N1108P-ON et deux ventilateurs refroidissent les commutateurs N1024T-ON/N1024P-ON/ N1048T-ON/N1048P-ON. Les ventilateurs ne sont pas remplaçables sur le terrain. Le commutateur N1108EP-ON n’est pas équipé d’un ventilateur. Résumé du modèle Série N1100-ON Tableau1-2.
Si vous installez plusieurs commutateurs dans un rack, montez-les de bas en haut. 1 Fixez le commutateur N1108T-ON/N1108P-ON dans le kit de plateau tandem Dell (Dell Tandem Tray Kit), comme illustré dans la Figure 1-1. Figure 1-1. Dell Tandem Tray Kit Guide de mise en route...
L REMARQUE: Le connecteur d’alimentation CA se trouve sur le panneau arrière des commutateurs N1108T-ON/N1108P-ON. Le connecteur d’alimentation CC du commutateur N1108EP-ON se trouve au centre du panneau arrière. REMARQUE: Le commutateur N1108EP-ON utilise un adaptateur secteur externe. Aucun kit de montage n’est disponible pour l’adaptateur secteur externe du commutateur...
2 Insérez les vis fournies dans les orifices de montage en rack et serrez-les à l’aide d’un tournevis. 3 Répétez l’opération de l’autre côté du commutateur. 4 Insérez l’assemblage du commutateur et du rail dans le rack depuis l’avant du rack. Assurez-vous de bien aligner les orifices de montage en rack du commutateur avec ceux du rack.
Page 44
2 Placez le support de montage mural fourni sur un côté du commutateur, en alignant bien les orifices de montage du commutateur avec ceux situés sur le support de montage mural. 3 Insérez les vis fournies dans les orifices du support de montage mural et serrez-les avec un tournevis.
Page 45
7 Percez les trous sur les emplacements que vous avez marqués et insérez les huit chevilles fournies dans les trous. 8 Insérez les vis fournies dans les orifices des supports de montage mural et serrez-les avec un tournevis. Voir la Figure 1-5. Figure 1-5.
Installation des N1124T-ON/N1124P- ON/N1148T-ON/ N1148P-ON Montage en rack d’un commutateur N1124T-ON/ N1124P-ON/ N1148T-ON/ N1148P-ON AVERTISSEMENT: Prenez connaissance des consignes de sécurité exposées Safety and Regulatory Information (Informations relatives à la dans le manuel réglementation et la sécurité) ainsi que des informations relatives à la sécurité des autres commutateurs qui se connectent au commutateur ou qui le prennent en charge.
Installation en tant que commutateur autonome REMARQUE: Dell recommande vivement de monter le commutateur dans un rack. Installez le commutateur sur une surface plane si vous ne l’installez pas dans un rack. La surface doit être capable de supporter le poids du commutateur et de ses câbles.
Démarrage et configuration des commutateurs Série N1100-ON Le diagramme qui suit donne une vue générale de la procédure à suivre pour effectuer la configuration initiale une fois que le commutateur a été déballé et monté. Diagramme du flux d’installation et de configuration Figure 1-7.
Vous pouvez télécharger les notes de mise à jour à partir du site web du support de Dell dell.com/ support. REMARQUE: Dell vous recommande de vous procurer la version la plus récente de la documentation utilisateur, disponible sur le site dell.com/support. Pour surveiller et configurer le commutateur via la console USB, utilisez le port de console sur le panneau avant du commutateur pour le connecter à...
3 Branchez le connecteur USB de type B du câble directement sur le port de console du commutateur. Le port de console du Dell Networking est situé sur le côté droit du panneau avant et est identifiable par le symbole |O|O|.
Démarrage du commutateur Série N1100-ON Lorsque le système est mis sous tension alors que le terminal local est déjà connecté, le commutateur effectue un POST (auto-test de démarrage). Ce test s’exécute chaque fois que le commutateur est initialisé et il vérifie les composants afin de déterminer si le commutateur est entièrement opérationnel avant de démarrer complètement.
• Le commutateur Dell Networking a bien démarré. • La connexion à la console a été établie et l’invite de l’Assistant Dell d’installation facile est affichée sur l’écran d’un PC exécutant un logiciel d’émulation de terminal. La configuration initiale du commutateur est effectuée via le port de console.
Procédure de configuration initiale Effectuez la configuration initiale à l’aide de l’ Assistant Dell d’installation facile ou en utilisant la CLI. L’Assistant démarre automatiquement si le fichier de configuration du commutateur est vide. Vous pouvez quitter l’Assistant à tout moment en entrant [Ctrl+Z], mais tous les paramètres configurés seront ignorés et le commutateur utilisera les valeurs par défaut.
Exemple de session Cette section décrit une session Assistant Dell d’installation facile. Les valeurs suivantes sont utilisées dans la session : • La chaîne de communauté SNMP à utiliser est public. • L’adresse IP du système de gestion du réseau (NMS) est 10.1.2.100.
Exemple de la console Assistant Dell d’installation facile L’exemple suivant contient la séquence d’invites et de réponses d’un exemple de session Assistant Dell d’installation facile avec les valeurs indiquées plus haut. Au démarrage du commutateur après le POST, la boîte de dialogue suivante s’affiche :...
Page 56
Dell. You further agree to allow Dell to transmit and store the Collected Data from SupportAssist in accordance with these terms. You agree that the provision of SupportAssist may involve international transfers of data from you to Dell and/or to Dell's affiliates, subcontractors or business partners.
Page 57
The wizard automatically assigns the highest access level [Privilege Level 15] to this account. You can use Dell Network Manager or other management interfaces to change this setting, and to add additional management system information later.
Page 58
Step 2: Now we need to set up your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface. You may set up other accounts and change privilege levels later. For more information on setting up user accounts and changing privilege levels, see the user documentation.
If the information is incorrect, enter (N) to discard the configuration and restart the wizard: [Y/N] y Thank you for using the Dell Easy Setup Wizard. You will now enter CLI mode. Applying Interface configuration, please wait...
Page 60
Pour plus d’informations sur la configuration des fonctionnalités du commutateur, reportez-vous au User Configuration Guide (Guide de configuration utilisateur) ou au CLI Reference Guide (Guide de référence de l’interface CLI) disponibles sur le site dell.com/support. Guide de mise en route...
Des câbles et des connecteurs correctement blindés et mis à la terre doivent être utilisés afin de respecter les limites d’émissions établies par la FCC. Dell EMC n’est pas responsable des interférences nuisibles à la réception radio ou télévision causées par des câbles et des connecteurs autres que ceux recommandés, ou par des modifications ou adaptations non autorisées...
Page 62
Figure 1-8. Déclaration du ministère canadien des Communications Normes de sécurité et certificats de conformité des organismes • IEC 62368-1, 2e édition • CUS UL 60950-1, 2e édition • Répond ou dépasse les exigences des tests de rigidité diélectrique et de continuité...
Page 63
Dell EMC encourage les propriétaires d’équipement informatique à recycler de manière responsable leur matériel lorsqu’il n’est plus utilisé. Dell EMC propose un large éventail de programmes et de services de retour de produits dans plusieurs pays pour aider les propriétaires à...
Page 64
Switches Dell Comutadores N1108T-ON/ N1108P-ON/N1108EP-ON/ N1124T-ON/N1124P-ON/ N1148T-ON/N1148P-ON Guia de Noções Básicas Modelos normativos: E17W e E18W...
Introdução Este documento fornece informações básicas sobre os comutadores Switches Dell Série N1100-ON, inclusive a forma de instalar o comutador e executar a configuração inicial. Para obter informações sobre como configurar e monitorar os recursos do comutador, consulte o Guia de configuração usuário, que está...
PSU principal 1,97A 459,06W Sistema de ventilação Um ventilador resfria os comutadores N1108T-ON/N1108P-ON e dois ventiladores resfriam os comutadores N1024T-ON/N1024P-ON/N1048T-ON/ N1048P-ON. Os ventiladores não podem ser substituídos em campo. O N1108EP-ON é um comutador sem ventilador. Guia de Noções Básicas...
Número do modelo de alimentação de modelo tipo normativo comercialização (PSU) normativo (RTN) (MMN) (RMN) N1108T-ON 10 portas SFP de 1G/2 portas DPS-24GP E17W E17W001 SFP de 1G N1108P-ON 10 portas SFP de 1 G/2 portas DPS-80AP/ E17W E17W001 SFP de 1 G/2 portas PoE+...
AVISO: Quando montar vários comutadores em um rack, faça-o de baixo para cima. 1 Prenda o comutador N1108T-ON/N1108P-ON no kit da bandeja em série Dell, conforme exibido na Figura 1-1. Figura 1-1. Kit de bandeja em série Dell 2 Insira o comutador no rack de 48,26 cm (19") rack, garantindo de que os orifícios de montagem de rack no kit se alinhem com os orifícios no rack.
(dependendo do tipo de rack que você possui). Aperte os parafusos na parte inferior antes de apertar os parafusos na parte superior. Montar um N1108T-ON/N1108P-ON/N1108EP-ON em um rack de dois postes usando suportes em L grandes NOTA: O conector de alimentação CA está...
3 Repita o processo no outro lado do comutador. 4 Insira o comutador e o conjunto do trilho no rack pela parte frontal do rack. Certifique-se de que os orifícios de montagem em rack no comutador estejam alinhados com os orifícios de montagem no rack. 5 Prenda o comutador ao rack com os parafusos do rack.
Page 74
3 Insira os parafusos fornecidos nos orifícios do suporte de montagem em parede e aperte-os com uma chave de fenda. Consulte Figura 1-4. Figura 1-4. Inserir suportes de montagem 4 Repita o processo para instalar o suporte de montagem em parede no outro lado do comutador.
Page 75
Figura 1-5. Montagem em uma parede Guia de Noções Básicas...
Instalação dos modelos N1124T-ON/ N1124P-ON/N1148T-ON/ N1148P-ON Montagem em rack dos comutadores N1124T-ON/ N1124P-ON/ N1148T-ON/ N1148P-ON ADVERTÊNCIA: Informações sobre Leia as informações de segurança em segurança e regulamentações , bem como as informações de segurança para outros comutadores que se conectam ou suportam o comutador. O conector de alimentação CA está...
Como instalar como um comutador autônomo NOTA: A Dell recomenda montar o comutador em um rack. Instale o comutador em uma superfície plana se não for instalá-lo em um rack. A superfície deve ser capaz de suportar o peso do comutador e de seus cabos.
Iniciar e configurar o comutador Série N1100-ON O fluxograma a seguir fornece uma visão geral das etapas que você usa para fazer a configuração inicial depois que o comutador é desembalado e montado. Fluxograma de instalação e configuração Figura 1-7. Guia de Noções Básicas...
NOTA: Antes de continuar, leia as Notas de versão do produto. Você pode fazer o download das Notas de versão no site de suporte da Dell em dell.com/support. NOTA: A Dell recomenda que você obtenha a versão mais recente da documentação do usuário no site de suporte da Dell em dell.com/support.
Windows). 3 Conecte o conector USB tipo B no cabo diretamente à porta do console do comutador. A porta de console Switches Dell está localizada no lado direito do painel frontal e está identificada com um símbolo |O|O|.
Inicializar o comutador Série N1100-ON Quando a alimentação é ativada com o terminal local já conectado, o comutador passará pelo teste automático de inicialização (POST). O POST é executado toda vez que o dispositivo é inicializado e examina os componentes de hardware para determinar se o comutador está...
• A conexão do console foi estabelecida e o prompt Assistente de configuração fácil Dell aparece na tela de um computador executando um software de emulação de terminal. A configuração inicial do comutador é efetuada através da porta do console.
NOTA: Se você não executar o Assistente de configuração fácil Dell ou não responder ao prompt inicial do Assistente de configuração fácil dentro de 60 segundos, o comutador entra no modo de interface de linha de comando. Você...
Sessão de exemplo Esta seção descreve uma sessão Assistente de configuração fácil Dell. Os valores a seguir são usados na sessão de exemplo: • A string de comunidade SNMP a ser usada é public. • O endereço IP do sistema de gerenciamento de rede (NMS) é 10.1.2.100.
Exemplo do console Assistente de configuração fácil Dell O exemplo a seguir contém a sequência de prompts e as respostas associadas à execução de uma sessão de exemplo do Assistente de configuração fácil Dell, usando os valores de entrada listados anteriormente.
Page 86
Dell. You further agree to allow Dell to transmit and store the Collected Data from SupportAssist in accordance with these terms. You agree that the provision of SupportAssist may involve international transfers of data from you to Dell and/or to Dell's affiliates, subcontractors or business partners.
Page 87
The wizard automatically assigns the highest access level [Privilege Level 15] to this account. You can use Dell Network Manager or other management interfaces to change this setting, and to add additional management system information later.
Page 88
Please enter the IP address of the Management System (A.B.C.D) or wildcard (0.0.0.0) to manage from any Management Station. [0.0.0.0]: 10.1.2.100 Step 2: Now we need to set up your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface.
If the information is incorrect, enter (N) to discard the configuration and restart the wizard: [Y/N] y Thank you for using the Dell Easy Setup Wizard. You will now enter CLI mode. Applying Interface configuration, please wait...
Page 90
Para acessar a interface do administrador de comutador Dell OpenManage, digite o endereço IP da interface de gerenciamento VLAN 1 no campo de endereço de um navegador da Web. Para acessar o gerenciamento remoto para CLI, digite o endereço IP da interface de gerenciamento VLAN 1 em um cliente SSH ou Telnet.
Cabos e conectores adequadamente blindados e aterrados devem ser usados para atender aos limites de emissão de FCC. A Dell EMC não é responsável por qualquer interferência de rádio ou televisão causada por usar outros cabos e conectores que não os recomendados ou por alterações ou modificações não...
Page 92
Figura 1-8. Declaração do Ministério de Comunicação do Canadá Padrões de segurança e certificações da entidade de conformidade • IEC 62368-1, 2ª edição • CUS UL 60950-1, 2ª edição • Atende ou supera os testes de continuidade de aterramento e de Hi Pot de acordo com a UL 60950-1.
Page 93
A Dell EMC incentiva os proprietários de equipamentos de tecnologia da informação a reciclar seus equipamentos de maneira responsável quando eles não forem mais necessários. A Dell EMC oferece uma variedade de programas e serviços de devolução de produtos em vários países para ajudar os proprietários de equipamentos a reciclar seus produtos...
Page 94
Conmutadores de Dell Conmutadores N1108T-ON/ N1108P-ON/N1108EP-ON/ N1124T-ON/N1124P-ON/ N1148T-ON/N1148P-ON Guía de introducción Modelos regulatorios: E17W y E18W...
Guía de configuración del usuario, que está disponible en el sitio web de asistencia de Dell en dell.com/support. Consulte el sitio web de asistencia técnica para obtener las últimas actualizaciones sobre documentación y firmware.
Page 99
Tabla 1-1. Consumo de energía para conmutadores PoE N1100-ON Series Modelo Voltaje de Configuración de la fuente Consumo de Potencia entrada de alimentación corriente fijo fija máxima máximo (A) N1108P-ON 100 V/60 Hz PSU principal 0,95 A 88,64 W 110 V/60 Hz PSU principal 0,87 A 88,43 W...
Sistema de ventilación Un ventilador enfría los conmutadores N1108T-ON/N1108P-ON, y dos ventiladores enfrían los conmutadores N1024T-ON/N1024P-ON/N1048T-ON/ N1048P-ON. Los ventiladores no son sustituibles en campo. N1108EP-ON es un switch sin ventilador. Resumen del modelo N1100-ON Series Tabla 1-2. Números reglamentarios del conmutador N1100-ON Series Nombre del Descripción...
PRECAUCIÓN: Cuando monte varios conmutadores en un bastidor, empiece desde abajo. 1 Fije el switch N1108T-ON/N1108P-ON en el kit de bandeja de tándem de Dell, como se muestra en Figura 1-1. Figura 1-1. Kit de bandeja Tandem Dell 2 Inserte el conmutador en el bastidor de 48,26 cm (19 pulg.), asegurándose de que los orificios de montaje del bastidor en el kit coinciden con los orificios de montaje en el bastidor.
L grandes NOTA: El conector de alimentación de CA se encuentra en el panel posterior de los switches N1108T-ON/N1108P-ON. El conector de alimentación de CC para el N1108EP-ON se encuentra en el centro del panel posterior. NOTA: El switch N1108EP-ON usa un adaptador de alimentación externo.
4 Inserte el ensamblaje de rieles y el switch en el rack desde la parte frontal del rack. Asegúrese de que los orificios de montaje en rack en el switch se alineen con los orificios de montaje del rack. 5 Fije el switch al rack mediante los tornillos. Ajuste el par de tornillos de la parte inferior antes de ajustar el de la parte superior.
Page 104
Figura 1-4. Inserción de los soportes de montaje 4 Repita el proceso con el soporte de montaje en pared del otro lado del conmutador. 5 Coloque el conmutador en la pared en la ubicación donde se instalará el conmutador. 6 En la pared, marque las posiciones donde deberán ir los tornillos para sujetar el switch.
Page 105
Figura 1-5. Montaje en pared Guía de introducción...
Instalación de N1124T-ON/N1124P- ON/N1148T-ON/ N1148P-ON Montaje en bastidor de un conmutador N1124T-ON/ N1124P-ON/ N1148T-ON/ N1148P-ON AVISO: Información reglamentaria y de Lea la información de seguridad en seguridad , así como la información de seguridad para otros conmutadores que se conectan al conmutador o que son compatibles con este. El conector de alimentación de CA se encuentra en el lado del conmutador.
Instalación como conmutador independiente NOTA: Dell recomienda encarecidamente montar el conmutador en un bastidor. Coloque el conmutador en una superficie plana si no va a instalarlo en un bastidor. La superficie debe poder soportar el peso del conmutador y de sus cables.
Inicio y configuración del conmutador N1100-ON Series El siguiente diagrama de flujo proporciona una descripción general de los pasos que debe seguir para realizar la configuración inicial una vez que el conmutador se haya desempaquetado y montado. Diagrama de flujo de instalación y configuración Figura 1-7.
NOTA: Lea las notas de publicación de este producto antes de continuar. Puede descargar las notas de publicación de la página web de asistencia de Dell en dell.com/support. NOTA: Dell recomienda encarecidamente que obtenga la versión más reciente de la documentación del usuario desde el sitio web de asistencia de Dell en...
Microsoft Windows). 3 Conecte el conector USB tipo B del cable directamente al puerto de la consola del conmutador. El puerto de la consola Conmutadores de Dell se encuentra en el lado derecho del panel frontal y está etiquetado con un símbolo |O|O|.
Inicio del conmutador N1100-ON Series Cuando se enciende la alimentación con el terminal local ya conectado, el conmutador realiza una autoprueba de encendido (POST). La autoprueba POST se ejecuta cada vez que se inicializa el conmutador y comprueba los componentes de hardware para determinar si el conmutador está completamente operativo antes del inicio completo.
• La conexión de la consola se estableció y la petición Asistente de configuración rápida de Dell aparece en la pantalla de un equipo que ejecute software de emulación de terminal. La configuración inicial del conmutador se realiza a través del puerto de la consola.
NOTA: Si no ejecuta Asistente de configuración rápida de Dell o no responde a la indicación inicial del Asistente de configuración en 60 segundos, el conmutador entrará en el modo CLI. Debe restablecer el conmutador con una configuración de inicio vacía para volver a ejecutar Asistente de configuración rápida de Dell.
Ejemplo de sesión Esta sección describe una sesión Asistente de configuración rápida de Dell. Los siguientes valores se utilizan en la sesión de ejemplo: • La cadena de comunidad SNMP que se utiliza es pública. • La dirección IP del sistema de administración de red (NMS) es 10.1.2.100.
El siguiente ejemplo contiene la secuencia de peticiones y respuestas asociadas a la ejecución de una sesión de ejemplo Asistente de configuración rápida de Dell, usando los valores de entrada presentados anteriormente. Cuando el conmutador finaliza la POST y se inicia, aparece el diálogo siguiente: Unit 1 - Waiting to select management unit)>...
Page 116
Dell. You further agree to allow Dell to transmit and store the Collected Data from SupportAssist in accordance with these terms. You agree that the provision of SupportAssist may involve international transfers of data from you to Dell and/or to Dell's affiliates, subcontractors or business partners.
Page 117
The wizard automatically assigns the highest access level [Privilege Level 15] to this account. You can use Dell Network Manager or other management interfaces to change this setting, and to add additional management system information later.
Page 118
Step 2: Now we need to set up your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface. You may set up other accounts and change privilege levels later. For more information on setting up user accounts and changing privilege levels, see the user documentation.
Para acceder a la interfaz del administrador de conmutadores OpenManage de Dell, introduzca la dirección IP de la interfaz de administración VLAN 1 en el campo de dirección de un navegador de Internet. Para la administración remota acceda a la CLI, introduzca la dirección IP de la interfaz de...
Page 120
CLI para configurar las características que su red requiere. Para obtener información acerca de cómo configurar las funciones del conmutador, consulte la Guía de configuración del usuario o Guía de referencia de la CLI disponibles en la web: dell.com/support. Guía de introducción...
Se deben utilizar conectores y cables de conexión a tierra correctamente blindados para cumplir con los límites de emisión de la FCC. Dell EMC no es responsable de las interferencias de radio o televisión ocasionadas por usar conectores y cables no recomendados o por modificaciones o cambios no autorizados en el equipo.
Page 122
Figura 1-8. Declaración del departamento canadiense de comunicación Certificaciones de agencias de cumplimiento de normas y estándares de seguridad • IEC 62368-1, 2.ª edición • CUS UL 60950-1, 2.ª edición • Cumple con o supera los requisitos de UL 60950-1 de pruebas de continuidad de conexión a tierra y de alta tensión.
Page 123
Dell EMC recomienda a los propietarios de tecnología de la información (TI) que reciclen sus equipos de manera responsable cuando ya no sean necesarios. Dell EMC ofrece una variedad de programas y servicios de devolución de productos en varios países, para ayudar a los propietarios de equipos a reciclar sus productos de TI.
Oficial Mexicana (NOM): Exportador: Dell Inc. One Dell Way Round Rock, TX 78682 Importador: Dell México, S.A. de C.V Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa Fe Delegación Álvaro Obregón, Ciudad de México. C.P. 01219 R.F.C: DME9204099R6 Enviar a: Dell México, S.A.