Operating the Controls (con't)
Humidity Control
This button allows you to adjust the humidity to suit your needs. This humidifier
will automatically cycle on and off as required to maintain the selected setting.
The readout displays both actual (ROOM) and desired (SET) humidity percentage
(%) settings when humidity control button is pressed. The ROOM readout has a
range of 20% to 95%. If the room humidity level is equal to or less than 20% the
display will show a flashing 20.
The SET readout has a range of 25% to 65% and is adjusted in increments of 5%.
Initially depressing the humidity button will display the current humidity setting.
Each additional press of the button increases the setting by 5%. A SET point of
65% operates the humidifier continuously regardless of the ROOM reading. The
humidistat that senses the readings is located on the power cord. Insure that it is
free from obstructions.
Using Your Humidifier
NOTE: During this time the room humidity level will continue to be monitored and
the humidifier will cycle the fan on and off until the filter is completely dry. The fan
will shut off leaving you with a dry humidifier that is less prone to mold and mildew
growth. If DRY OUT MODE is not desired, refill the humidifier with water and the
fan will return to the set speed.
NOTE: Fan automatically switches to lowest speed during DRY OUT MODE.
Refill Display
For maximum run time both the bottle
and the base should be filled. When
both the bottle and the base are empty
the display alternates the room
humidity reading and "F" (FILL),
indicating that additional water is
required. Also at this time the unit will
automatically switch into DRY OUT
MODE and continue to run on the
lowest speed until the filter is dry.
Check Filter Indicator
The ability of any humidifier to efficiently
supply humidity output relies heavily on the
condition of the filter. As the filter loads with
impurities it gradually loses its wicking
capability. When this happens, moisture
output is reduced and the humidifier has to
work longer to satisfy the selected setting.
This humidifier has a check filter reminder
timed to appear after 720 hours of
operation. When display shows an
alternating "CF" and the room humidity
setting at 5 second intervals, it is a reminder
to check the filter condition
.
8
Refill
Indication
Check Filter
Indication