Installation and use
Prior to commencing installation or use read ins-
tructions carefully and follow all directions! Pass
these instructions on to the system operator and
retain for later reference!
Warning information
Please read and follow the warning information in
these instructions. Disregard of the warning infor-
mation may lead to injury or material damage!
Labelling of important warning information:
Warning! Indicates hazards that may
lead to injury, material damage or
contamination of drinking water.
Note! Indicates hazards that may
lead to damages to the system or
malfunctions.
Important notes for the system plumber
Technical Data
Media
Admission pressure
Max. Operating temperature
Max. admission pressure
Output pressure
Output pressure
pre-set at the factory
Noise control
PRV
4 /16 – K41007100G001-00 / 05.2022 – © www.kemper-olpe.de
Safety instructions for installation
4
5
10
11
12
water, compressed-air,
neutral non-adhesive
liquids and gases
PN 16
30 °C
16 bar
1,5 - 6 bar
4 bar
Noise Control Class (ISO
3822) to
DN 32)
DIN EN 1213 |
DIN EN 1567
Use
To ensure correct use always make sure to only
install the pressure reducer in places where the
operating pressure and temperature do not exceed
the design criteria on which the order is based.
The manufacturer shall not be responsible for
amage caused by outside forces or other external
influences! Hazards at the pressure reducer caused
by the flow medium and operating pressure are to
be avoided through appropriate measures.
Note! The PRV are considered for cold
water only.
The Product has to be installed in a
housing or similar structure, where
light is excluded.
Only use the pressure reducer
•
or the specified purpose
•
in satisfactory condition
Inspection / maintenance
An annual inspection/maintenance according to
DIN EN 806-5 has to be done by the operator/
the installer. To avoid malfunction caused by dirt
and attrition, the device should be maintained on
a regular basis. The periods for the maintenance
depend on the operating conditions. Close shut-off
units before and after the pressure reducer. With
the key provided, slacken the Allen screws on the
valve housing and remove the pressure reducer
cartridge with housing from the base module in
the downward direction.
Liability
No warranty or liability will be accepted in case of:
•
Non-compliance with the instructions.
•
Incorrect installation and/or operation.
•
Unauthorised modification of the product.
•
Other incorrect operation.