TROUBLESHOOTING

PROBLEM
APPLIANCE DOES NOT OPERATE
VIBRATION OR RATTLING (Slight
vibration is normal .)
COMPRESSOR MOTOR OPERATES
FOR LONG PERIODS OR CYCLES
ON AND OFF FREQUENTLY
COMPARTMENT TOO WARM
APPLIANCE HAS ODOR
DOOR NOT CLOSING PROPERLY
MOISTURE FORMS ON OUTSIDE
OF APPLIANCE
FROST OR MOISTURE COLLECTS
INSIDE
49-60432-9
POSSIBLE CAUSE
• Appliance is so quiet that most of the time you will hear low or no operating
noise.
• Appliance may be in defrost cycle when compressor motor does not
operate for about 30 minutes.
• Controls are set to OFF. Press ON/OFF button on control panel.
• If interior light is not on, appliance may not be plugged in at electrical outlet.
Push the plug completely into the electrical outlet.
• The GFCI circuit breaker is tripped. Replace fuse or reset the breaker.
• The appliance is in showroom mode. Unplug it and plug it
back in.
• Adjust the leveling legs as shown in the Installation Instructions.
• Normal when appliance is first plugged in. Wait 24 hours for the appliance
to completely cool down.
• Often occurs when large amounts of beverages are placed in appliance.
This is normal.
• Door left open or package holding door open.
• Hot weather or frequent door openings. This is normal.
• Temperature control set at the coldest setting. See Temperature Control.
• Temperature control not set cold enough. See Temperature Control. Allow
24 hours for temperature to change.
• Warm weather or frequent door openings.
• Door left open for long time.
• Package may be holding door open.
• Thermistor may be blocked, which can affect the overall temperature. The
thermistor is located on the right-hand side, just above the third shelf.
• Interior needs cleaning. See Care and Cleaning.
• Keep open box of baking soda in appliance; replace every 3 months.
• Door gasket is sticking or folding over. Apply petroleum jelly or paraffin wax
to the face of the gasket.
• The door is hitting an internal component inside the appliance. Adjust
interior components to prevent interference.
• Not unusual during periods of high humidity. If bothersome, wipe surface
dry; otherwise, moisture will evaporate in time.
• Door left open or package holding door open.
• Too frequent or too long door openings.
• In humid weather, air carries moisture into appliance when door is opened.
• Temperature control set at coldest setting.
• Thermistor may be blocked, which can affect the overall temperature. The
thermistor is located on the right-hand side, just above the third shelf.