EN
INSTRUCTIONS FOR THE USE
IMPORTANT
Expiry date on the box
Read these instructions carefully and keep them in a safe place.
The half mask of 8000 and 8000next Series have been manufactu-
red in accordance with the EN405:2001+A1:2009 standard.
This half mask is classified as a III Category Personal Protection
Device, in accordance with European Regulation 425/2016. For
8000 and 8000next Series models three versions are produced that
are easily identifiable by means of the marking on the mask.
8400
ABEK1P3 R D 8400next
8600
A2P3 R D
8600next
8100
A2P2 R D
8100next
* the color refers to the marking on the half mask
This mask must only be used in accordance with the following
instructions. The manufacturer cannot accept any responsibility for
any damage resulting from improper use, the use of pirate parts, or
failure to comply with these instructions.
As an unassisted protection device, this half face mask does not
supply compressed or oxygen-enriched air, but only allows air
purified by the filter(s) to be drawn from the immediate environment,
by the normal breathing process.
This half face mask may only be used where the oxygen level in the
air exceeds 17% by volume.
This half face mask may only be used in environments containing
gases with a particular odour or taste. For the use in potentially
explosive environments respect the standards required by the
current safety and on-the-job injuries code.
This mask should not be used in confined spaces such as cisterns,
ducts, or underground.
Abandon the area of work immediately if:
- the half face mask has been damaged;
- breathing becomes laboured or difficult;
- symptoms of dizziness and/or fuzziness are felt;
- the nature and concentration of the contaminant is unknown.
Persons that have beard or moustache that protrudes from the mask
should refrain from using this apparatus, as these may impair the fit
and efficiency of the mask.
No alteration must be made to the mask. Any unauthorised
modification, even of a minor nature, shall cause the guarantee to
fall away, as well as any responsibility on the part of the manufactu-
rer towards third parties.
This half face mask should be used by personnel that are properly
trained and that have the relevant experience.
Masks that are still useable should be kept in a closed container,
and protected from dust, dirt, harsh light humidity, or heat sources.
When moving or storing the masks, make sure that the packaging is
intact and cannot be damaged by sharp objects or materials that
could perforate the filters, and that the filters will not be deformed by
being subjected to excessive loads. The worker shall leave
immediately the work area and replace the filters when he starts to
smell the gas odour with gas filters or when he starts to perceive an
increase of the breathing resistance with particle filters. The half
mask has a duration of 5 years from the first use of the product. For
transport use original packaging.
The CE 0426 – EN 405:2001 marking is printed on the half face
mask:
- CE indicates that it complies with the basic health and safety
requirements, as laid down in Annex II of European Regulation
425/2016 and in conformity to EN 405:2001 European Standard.
- The number 0426 identifies the Notified Body ITALCERT S.r.l.-
Viale Sarca, 336 - 20126 Milan (Italy) in charge of control pursuant
to module D of the European Regulation 425/2016
- The number EN 405:2001 identifies the European standard and
the date of its promulgation for Europe. This standard lays down the
minimum requirements for a half masks to be used as a respiratory
system protection device, and also lays down practical and
laboratory tests to be carried out to ensure that the particular model
conforms to the requirements.
ABEK1P3 R D (yellow)*
A2P3 R D (white)*
A1P2 R D (green)*
6
BLS protection devices are not designed to meet the provisions of
Directive 2014/34/EU.
The respirator must be stored in environment with temperature range
between -10 °C and +50 °C and with a relative humidity <80%.
BEFORE USING
This half face mask must always be checked before use. Defective
parts must be replaced before using. In particular:
- Check that the half face mask is clean, and in perfect working
order.
Remove the cover of the exhaust valve to check both the cleanliness
of the inside of the valve housing, as well as the valve itself. The
latter must be clean, and free of any deformation or breakage.
- Check that the harness is complete.
- Check all plastic parts for breakage.
CLEANING
The respirators from 8000 and 8000next Series can be used for
more that a single shift (8 hours). If the wearer decides to re-use the
mask this should be cleaned at the end of each shift according with the
following instructions. Clean the faceseal with a cloth moistened in hot
soapy water (not upper than 40°C). Do not allow the filters to come in
contact with the cloth and/or with the soapy water. Do not immerse
the product in water. Ensure that the mask is completely dry before
placing in storage. Store the respirator in a suitable bag or container
in a dry and non-contamined area. Note the name of the wearer and
the date when the original packaging has been opened.
WEARING
1. Fasten the lower elastic band behind the neck and put the head into
the half-mask, placing the chin in contact with the lower lip of the
mask.
2. Mate the mask on the nose area.
3. Hold the mask in place with one hand while positioning the head
harness with the other hand.
4. Adjust upper straps by pulling in the direction shown in figure 4
and the lower straps by pulling in the direction shown in figure 5. Do
not pull the elastic bands excessively.
Make sure that the mask is worn with the correct inclination (slightly
downward) to reach the perfect fit.
CHECKING THE FIT
While wearing the mask, close either the filters using the palm of the
hands and take a deep breath. If air does not escape from borders it is
well donned. If different, re-position the mask, increase the tension
on the harness straps, and repeat the test until a suitable result is
obtained.
DISCARD
Contaminated respiratory protective equipments, or components, or
any of the materials used to clean or disinfect respiratory protective
equipments, may need to be considered as hazardous waste. This will
depend upon specific substances wearers are exposed together with
amounts generated. In some cases specific legislation may apply.
MARKING
Manufacturer's registered Trademark.
Indicates year (central circle) and month (arrow) of
production.
8400 and 8600 have a NPF (nominal protective factor) of 33XTLV.
8100 have a NPF (nominal protective factor) of 12XTLV.
R
8000 and 8000next Series half masks are reusable products.
D
8000 and 8000next Series meets clogging requirements and
is marked D. This means that they have good performance and
long service life even in very dusty environments.
These Instructions for use have been approved by Italcert Srl
(Notified Body n° 0426), with the release of the EU type examination
of these products as a III Category Personal Protective Equipments
(PPE).
Declarations of conformity of the products are available in the
reserved area of the website www.blsgroup.com