Page 6
A terminal bar marked "GROUND" is provided within the controller. To reduce
the risk of electrical shock which can cause serious injury or death, connect this
terminal bar to the grounding terminal of your electric service or supply panel with
a continuous copper conductor having green insulation and one that is equivalent
in size to the circuit conductors supplying this equipment, but no smaller than no.
12 AWG (3.3mm
). In addition, a second wire connector should be bonded with a
2
no. 8 AWG (8.4mm
within five (5) feet (1.52m) of the pool/spa. In Canada the bonding wire must be
minimum 6 AWG (13.3mm
A ground-fault circuit-interrupter must be provided if this device is used to control
underwater lighting fixtures. The conductors on the load side of the ground-fault
circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other
conductors unless the additional conductors are also protected by a ground-fault
circuit-interrupter. Refer to local codes for complete details.
Attention installer: Install to provide drainage of
compartment for electrical components.
SAVE THESE INSTRUCTIONS
ENGLISH
WARNING
) copper wire to any metal ladders, water pipes, or other metal
2
).
2
CAUTION
AquaLink
AquaLink
Z4 | Owner's Manual
Z4 | Owner's Manual
®
®