Télécharger Imprimer la page

Cherry eVolution ERGO-SHARK R wireless Mode D'emploi page 6

Publicité

Congratulations!
When you select a quality product from Cherry, you've
always made the right choice.
The following features in particular set your
ERGO-SHARK R apart:
A laser sensor for greatest precision
Recharging while the system is in active operation
with charge display via the scroll wheel
Multistation-capable: Several mice can be used in
the same room without interfering with each other.
All 7 buttons are freely programmable with the
KeyM@n software. Try it and see!
For information on additional products, downloads,
and much more, please visit www.cherrycorp.com or
www.cherry.de
We hope you enjoy your new ERGO-SHARK R.
Your Cherry GmbH
1
Tips
1.1 Surface under the mouse
A bright, structured surface under the mouse
increases the efficiency of the mouse and ensures
optimum detection of movement.
A reflective surface is not suitable for use under the
mouse.
1.2 Tips for charging the alkaline batteries
A complete charge of the alkaline batteries lasts
approx. 12 to 18 hours. The charging circuit prevents
overcharging.
You must charge the batteries when the mouse wheel
flashes red.
Proper charging extends the service life of the alkaline
batteries.
Rechargeable alkaline batteries have the following
advantages:
high capacity (1800 mAh)
minimal self-discharge
can be recharged at any time without the memory
effect
rechargeable several hundred times
high output voltage (1.5 V)
environmentally friendly due to less waste
1.3 RSI syndrome
RSI syndrome
RSI stands for "Repetitive Strain Injury". RSI results
from small, continually repeated movements.
Typical symptoms are discomfort in the fingers or
neck. For further information see: www.cherry.de/
english/service/servicedownload_rsi.htm
1 Set up your workspace for maximum ergonomic
benefit.
2 Position the keyboard and mouse in such a way
that your upper arms and wrists are on either side
of your body and are stretched out.
3 Take several short breaks, with stretching exer-
cises if necessary.
4 Change the position of your body often.
1.4 Disposal
Dispose of the old unit and the batteries
via a collecting point for electronic scrap
or via your dealer.
2
Troubleshooting
1 Make sure the mouse is turned on.
2 Charge the mouse with the charging cable
(included with delivery).
3 Connect the receiver to another USB port on the
PC.
3
Technical data
Designation
Supply voltage mouse
Supply voltage receiver
Current consumption
mouse
Current consumption
receiver
Battery type mouse
Storage temperature
Operating temperature
Value
2.0 ... 3.3 V SELV
5.0 V/DC ±5 % SELV
max. 12 mA
typ. 30 mA
2 rechargeable alkaline
batteries,
type AA (LR6)
–20 °C ... +60 °C
0 °C ... +40 °C

Publicité