Configurable Settings - MSA 10175021-SP Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

Configurable Settings

The following settings are configurable to the user's preference using MSA's Fire Service account-
ability software.
Customized Palettes
Sleep Mode and Tilt
Thermography
TIC Auto On
Default Setting:
The G1 SCBA with Integrated TIC
will come pre-configured with 5
different palettes and the default
palette will be White Hot.
When the Integrated TIC is in TIC
mode and suspended vertically or
titled down for 10 seconds the Inte-
grated TIC will enter sleep mode to
conserve power. Sleep mode will
turn off the TIC backlight and the
display will go blank. When the Inte-
grated TIC is tilted back "up" or into a
horizontal orientation the Integrated
TIC will wake up and return to the
standard TIC mode.
The G1 SCBA with Integrated TIC is
capable of performing thermography
with temperature outputs visible in
the top right corner of the display
window when using TIC mode.
Integrated Thermal Imaging Camera
Configurable Settings
Configuration Options:
The G1 SCBA with Integrated TIC
can be configured to have between
1 and 5 different palettes and all 5
palettes can be customized by the
end user.
One palette must always be
selected as the default.
The Integrated TIC can be config-
ured to enter sleep after 5 minutes
of being tilted down.
Note:
Battery consumption will be
affected in this configuration.
The thermography feature can be
configured to report temperature in
units of Fahrenheit or Celsius.The
thermography feature can also be
disabled entirely.
The G1 SCBA with Integrated TIC
can be configured to enter TIC
mode immediately upon startup
without user interaction.