How to connect
Fibre optic connection
RX1
RX2
LD-63
TX1
TX2
RS-232/V.24
or
RS-422/485
NB When a multidrop connection ends with an LD-63 and the fibre pair is
connected on channel 2, the switch S1:2 must be set (Y-mode)
Connection of RS-232/V.24, RS-422, RS-485
RS-232/V.24
equipment
SG TD RD
PWR
TD RD
OPTO LINK MONITOR
LD-64
Rx1
*) The designations T+, T–, R+, R– are not standardised and may vary between different manufactures. The first step
in fault finding is to reverse the cables (swap T+ with T– and/or R+ with R–). Please note that this should be
done only at one end!
6072-2005