W orking logic
"Step-by-Step" logic (Dip 1 = OFF Dip 2 = ON)
A Start control puts into motion, a following control stops the motion, a further Start control reverses the motion (direction reverse).
"Automatic closing" (Dip 1 = ON Dip 2 = ON)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied during the pause interrupts work
cycle and the gate doesn't close automatically. Photocell intervention during pause time reloads it, extending the period before automatic closing.
"Condominium" logic (Dip 1 = irrelevant Dip 2 = OFF Dip 3 = irrelevant)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied while opening is irrelevant. A Start
control supplied while closing provokes the stop and gear reverse after approx. 1,5 sec.. A Start control or Photocell intervention during pause
time reloads it, extending the period before automatic closing. .
WARNING: after each modification of the working logic, switch the control unit off and on again to make the change active.
"Immediate closing" (DP3=ON
DP2=ON)
In opening phase and during pause time, after having passed the Photocell, it determines the stop and, after 1,5 sec., gate closing.
Electric power lack
Following to a temporary electric power lack, at recovery the first Start control determines an opening cycle.
"Single leaf" operation
In single leaf operation, the operating logics described above remain unchanged.
In case of single leaf gate, set DP5=ON and connect the leaf to the motor M2.
Programming
Learning of remote controls
To enter a START code, press the P1 key once. To enter a PEDESTRIAN START code, press the P1 key twice. To enter a COURTESY LIGHT code,
press the P1 key three times. Each time the P1 key is pressed, the DL1 led emits a short flash. After 3 seconds from the last pressure of P1, the DL1
led turns on with a steady light. Then press the key to be memorized on the remote control. The DL1 led will switch off, indicating that the code has
been memorized. If the code is not recognized, the DL1 led stays on for 10 sec., after which it will automatically switch off.
Erasing of all memorized codes
To delete all the stored codes, keep the P1 key pressed for approx. 10 sec. until the DL1 led turns off.
Setting of pause time and the M2 motor's closing delay
To set the pause time, press the P2 key once. To set
the M2 motor's closing delay,
press the P2 key twice. Each time the P2 key is pressed, the DL1
led emits a short flash. After 3 seconds from the last pressure of P2, the DL1 led turns on with a steady light. Let pass the time corresponding to the
desired time and press again the key P2.
Programming of work time for M1 leaf
Rotate the RV1 trimmer to the maximum clockwise. Make sure the leaf M1 is completely closed. Press button P3 for about 3 sec., DL1 led will
turn on with steady light. Press the P1 key to open the M1 leaf with reduced speed. At the end of opening, press the P1 key to close the M1 leaf
with the maximum speed. At the end of closing, press P1 key again to stop the leaf.
Programming of work time for M2 leaf
Rotate the RV1 trimmer to the maximum clockwise. Make sure the leaf M2 is completely closed. Press button P3 for about 3 sec., DL1 led will
turn on with steady light. Press the P2 key to open the M2 leaf with reduced speed. At the end of opening, press the P2 key to close the M2 leaf
with the maximum speed. At the end of closing, press P2 key again to stop the leaf.
Electrical and mechanical features
Dimensions and weight (with box): 177 x 247 x 92 mm - 1,2 Kg
Main power supply: 230 Vac +/- 10%
Stand-by power consumption: approx. 1 W
Operating temperature range: 0 to + 60 °C
Single-phase motors power supply: 230 Vac 1 HP max
Blinker power supply: 230 Vac 40 W max
Courtesy light power supply: 230 Vac 100 W max
Open gate lamp power supply: 230 Vac 40 W max
Electric lock power supply: 12 Vac 15 W max
Operating frequency: 433,92 or 868,35 MHz
DECLARATION OF CONFORMITY
Unit description: Electronic board controlling 1 or 2 230 Vac single-phase asynchronous motors destined to swing gate automation.
Model: CTR320
Applied rules: EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1
Test laboratory: NEMKO SPA
Outcome: Positive
The manufacturer declares that the above listed products comply to the norms provided for by European directives 2004/108/EC and 2006/95/EC.
Date: 22-06-2020