INSTALLATION INSTRUCTIONS
CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
OUTDOOR KITCHEN PROFESSIONAL RANGE HOODS: are approved for use in covered
outdoor kitchens only. Proper duct adapters, ducting, chimneys, roof/wall caps, etc. must be
utilized as called out in the following instructions. Do not install the hood in an uncovered area
directly exposed to the elements.
SECTION 1
Preparing the Insert
1.
Unpack hood from the carton and confirm that all pieces are present. In addition to the
range hood you should have:
1 - Grease Trough
2 - Grease Baffles
2 - Halogen Lamps
1 - Instruction/Safety Sheet
NOTE: Some hoods may be shipped with a protective plastic adhered to the underside of the
unit. It is recommended to leave this in place during installation to protect it from scratching.
Remove when the installation is complete.
SECTION 2
Preparing the Area
CAUTION:
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION:
WHEN CUTTING OR DRILLING INTO WALL DO NOT
DAMAGE ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.
1.
PIN28: Cut a hole 26.88" wide by 15.25" deep into the cabinet or canopy the power unit
will be mounted into.
PIN30: Cut a hole 30.75" wide by 17.5" deep into the cabinet or canopy the power unit
will be mounted into (Figure 1):
26.88" / 30.75"
Figure 1
NOTE: The hood must be mounted a minimum of 24" and a maximum of 36" from the
cooking surface.
SECTION 3
Optional Hood Liner
1.
Secure the liner to the cabinet frame or custom canopy using three screws on each end of
the liner and three screws on each side of the top of the liner (Figure 2).
Figure 2
CAUTION:
MAKE SURE THE SURFACE YOU ARE MOUNTING THE
INSERT AND LINER TO IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT.
OTHERWISE YOU WILL NEED TO REINFORCE THE AREA.
6728026 Rev. E 1-16
MAKE SURE POWER IS SWITCHED OFF AT
MAKE SURE POWER IS SWITCHED OFF AT
15.25" / 17.5"
www.airkinglimited.com
SECTION 4
Installing the Insert
NOTE: If cabinet frame work does not exist, you will need to install framing to secure the unit
to (Figure 3).
22.5"
Support
Figure 3
1.
Install the insert unit into the hole and secure in place using ten screws (not included)
(Figure 4).
Figure 4
NOTE: If an Air King hood liner is being utilized, use the screws provided with the hood liner to
attach the power unit to the liner.
CAUTION:
MAKE SURE THE SURFACE YOU ARE MOUNTING THE
POWER UNIT TO IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT.
OTHERWISE YOU WILL NEED TO REINFORCE THE AREA.
SECTION 5
Ducting
CAUTION:
ALL DUCTING MUST COMPLY WITH LOCAL AND
NATIONAL BUILDING CODES.
WARNING:
METAL DUCTWORK.
Determine the type of ducting you will require (Figure 5).
1.
Horizontal
Wall Cap
Figure 5
NOTE: For models using the B300, B500, or B600 blowers, a minimum of 6" diameter outlet adapter
& ducting is required to achieve the proper air flow. The B900 requires a minimum 8" diameter
adapter and ducting, while the B1125 requires a minimum 10" diameter adapter and ducting.
NOTE: When the duct termination is similar to that shown in Figure 5 (passing through the wall
to which the hood is mounted) the installation requires special consideration. Depending upon
where the wall studs are located, it may be necessary to cut one or more of the wall studs and
install a header and footer to transfer the load to the adjacent studs. Additional studs may need
Width of
Cabinet
2"
2"
12"
TO REDUCE THE RISK OF FIRE, USE ONLY
Roof Cap
Outlet
Adapter
Vertical
2 of 12