Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Professional Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
1.
Read all instructions before installing or using range hood.
2.
Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
3.
Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
4.
Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
5.
Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
6.
When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO
ATTICS, CRAWL SPACES, OR GARAGES.
7.
This unit must be grounded.
8.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
111597000 Rev. A 5-07
Get user manuals:
See SafeManuals.com
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
WARNING:
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambéing food (ie. Crepes Suzette, Cherries Jubilee, Peppercorn
Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
WARNING:
THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
I. You know you have a Class ABC extinguisher, and you already
know how to operate it.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING:
DUCTWORK.
www.airkinglimited.com
Range Hood
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
TO REDUCE THE RISK OF INJURY TO PERSONS IN
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
1 of 16

Publicité

loading

Sommaire des Matières pour Air King Professional Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Professional Series Range Hood READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS It is highly recommended that a back draft damper be installed to prevent outside air from flowing back into the home. Choose a back draft damper (available separately) sized to fit the diameter of the outlet adapter. Attach CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL the back draft damper into the outlet adapter, press fit it into the round...
  • Page 3 Rest the cavity on the back side of the hood on the wood strip and secure SECTION 5 hood to wood strip with the included 3/4" screws through the holes in the Installing the Range Hood back of the hood that line up with the wood strip (use 6 screws for 30" and 36"...
  • Page 4 If the grease baffles become damaged, replace easiest to install the spacer(s) first and the grease filters last (Figure 11). with Air King Model PHGB1, PHGB2, or PHGB3 Grease Baffles. CAUTION: ALLOW BULB TO COOL BEFORE REPLACING.
  • Page 5 In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original bill of sale showing: date of purchase, place of purchase and model purchased.
  • Page 6 INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Séries Professionnelles Hotte de Cuisine LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 7 INSTRUCTIONS D’INSTALLATION Il est fortement recommandé qu’un clapet anti-retour soit installé pour prévenir que l’air extérieur circule vers la maison. Choisir un clapet anti- retour (disponible séparément) de taille appariant le diamètre de l’adaptateur AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST de sortie.
  • Page 8 Faire reposer la cavité sur le côté arrière de la hotte sur la bande de bois SECTION 5 et fixer à la bande de bois avec les vis de 1,9 cm comprises au travers des Installation de la hotte trous dans l’arrière de la hotte qui s’alignent avec la bande de bois (utiliser les 6 vis pour les largeurs de 76,2 et de 91,4 cm et 8 vis pour les largeurs Mesurer et marquer une ligne de niveau sur le mur au-dessus de la surface supérieures).
  • Page 9 Si le dalot à graisse rétractable compris n’est pas déjà installé dans la REMARQUE : Sur les installations où un ventilateur à une (1) seule vitesse est hotte, l’insérer dans le canal intérieur arrière de la hotte. Assurez-vous que utilisé, tous les contrôles du ventilateur opèrent à la même vitesse. Sur les le côté...
  • Page 10 GARANTIE LIMITÉE Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 11 INSTRUCCIONES IMPORTANTES – MANUAL DE OPERACIÓN Campana de Serie Profesional Extracción LEA Y GUARDE ESTAS INSTRUCCIONES LEA CUIDADOSAMENTE ANTES DE INTENTAR MONTAR, INSTALAR, OPERAR O MANTENER EL PRODUCTO DESCRITO. PROTÉJASE A USTED MISMO Y A LOS DEMÁS OBEDECIENDO TODA LA INFORMACIÓN DE SEGURIDAD. ¡EL HECHO DE NO CUMPLIR CON LAS INSTRUCCIONES PODRÍA RESULTAR EN DAÑOS PERSONALES Y/O A LA PROPIEDAD! CONSERVE LAS INSTRUCCIONES PARA REFERENCIA FUTURA.
  • Page 12 INSTRUCCIONES DE INSTALACIÓN Es altamente recomendable la instalación de un regulador de corriente invertida de aire para evitar que el aire exterior vuelva a ingresar a la casa. Elija un regulador de corriente invertida de aire (disponible por separado) del tamaño CUIDADO: ASEGÚRESE QUE EL SUMINISTRO ELÉCTRICO ESTÉ...
  • Page 13 Apoye la cavidad en la parte posterior de la campana sobre el listón de madera SECCIÓN 5 y asegure la campana a dicho listón con los tornillos de 19,05 mm incluidos Instalación de la campana extractora a través de los orificios en la parte posterior de la campana que coinciden con el listón de madera (use 6 tornillos para anchos de 762 mm y 914,4 mm y Mida y marque una línea de nivel en la pared encima de las hornillas de la 8 tornillos para anchos mayores) Asegure la parte inferior de la campana...
  • Page 14 SECCIÓN 9 Acabado de la Instalación , para retirar los deflectores y la canaleta. primero y los filtros de grasa después (Figura 11). Si los deflectores de grasa se dañan, reemplácelos con deflectores de grasa Air King Modelos PHGB1, PHGB2, o PHGB3. Canal PRECAUCIÓN: DEJE ENFRIAR LA BOMBILLA ANTES DE CAMBIARLA.
  • Page 15 Para hacer un reclamo sobre esta garantía, usted debe ser el consumidor original del producto. Usted deberá presentar a Air King la factura original de la venta mostrando: fecha de compra, lugar de compra y modelo comprado. El hecho de con cumplir con estos requisitos anulará su garantía.
  • Page 16 NOTES / NOTAS 111597000 Rev. A 5-07 16 of 16 www.airkinglimited.com Get user manuals: See SafeManuals.com...