Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models:
LE600A, LE600, L600
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electric shock and injury to
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE
FOLLOWING:
a)
Use this unit only in the manner intended by the manufacturer.If you have questions,
contact the manufacturer.
b)
Before servicing or cleaning the unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE
FOLLOWING:
a)
Installation work and electrical wiring must be done by qualified person(s) in accordance
with all applicable codes and standards, including fire-related construction.
b)
Sufficient air is needed for proper combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c)
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION:
PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT
VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL
SPACES, OR GARAGES.
d)
Ducted fans must always be vented to the outdoors.
e)
This unit must be grounded.
f)
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
g)
Read all instructions before installing or using range hood.
WARNING:
SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED
CONTROL DEVICE.
6727921 Rev. F 12-18
OPERATING MANUAL
AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE ONLY. DO NOT
TO REDUCE THE RISK OF FIRE AND TO
TO REDUCE THE RISK OF FIRE, ELECTRIC
SAVE THESE INSTRUCTIONS
WARNING:
GREASE FIRE:
a)
Never leave surface units unattended at high settings. Boil overs cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b)
Always turn hood ON when cooking at high heat or when flambéing food (ie. Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c)
Clean ventilating fans frequently. Grease should not be allowed to accumulate on
fan filter.
d)
Use proper pan size. Always use cookware appropriate for the size of the surface
element.
WARNING:
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a)
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off
burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
b)
NEVER PICK UP A FLAMING PAN - You may be burned.
c)
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d)
Use an extinguisher ONLY if:
I.
You know you have a Class ABC extinguisher, and you already know how to
operate it.
II.
The fire is small and contained in the area where it started.
III.
The fire department is being called.
IV.
You can fight the fire with your back to an exit.
WARNING:
METAL DUCTWORK.
WARNING:
THE BUILDING HAS A STRONG EFFECT ON THE AIR FLOW, NOISE AND ENERGY
USE OF THE FAN. USE THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE ENERGY LOSS AND
INHIBIT MOLD GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT ACHIEVE
THEIR RATED AIRFLOW.
www.airkinglimited.com
Power Unit
TO REDUCE THE RISK OF A RANGE TOP
TO REDUCE THE RISK OF INJURY TO PERSONS
TO REDUCE THE RISK OF FIRE, USE ONLY
THE DUCTING FROM THIS FAN TO THE OUTSIDE OF
1 of 12

Publicité

loading

Sommaire des Matières pour Air King LE600A

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Power Unit Models: LE600A, LE600, L600 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 It is recommended to leave this in place during installation to protect it from scratching. Remove when the installation is complete. NOTE: If an optional Air King Liner is not being used; use appropriate hardware to install the unit in place, making sure to comply with all Local and National Building Codes.
  • Page 3 IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF LE600A, LE600: Two GU10 Base 7W maximum LED lamps INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. L600: Two GU10 Base 50W maximum Halogen lamps Turn switches to the OFF ( •...
  • Page 4 WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 5 Fan Switch 5S1144085 Light Switch 5S4199018 Switch Plate 5S1142010 Knob 5S1142011 GU10 Lamp Holder Assembly 5S1137702 7 Watt LED Lamp (LE600A, LE600) 5S1999726 50 Watt Halogen Lamp (L600) 5S1137038 Grease Filters 5S1137041 Wire Assembly (LE600, L600) 5S1157100 Wire Assembly (LE600A) 5S1157101...
  • Page 6 NOTES 6727921 Rev. F 12-18 www.airkinglimited.com 6 of 12...
  • Page 7 INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Unité de puissance Modèles: LE600A, LE600, L600 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 REMARQUE : Certaines hottes de cuisine peuvent être livrées avec une pellicule protectrice en REMARQUE : Si un revêtement Air King facultatif n'est pas utilisé ; utilisez le matériel plastique collée sur le dessous de l’unité. Il est recommandé de laisser cette pellicule en place durant approprié...
  • Page 9 PAS plus que nécessaire. LOCAUX, LES ORDONNANCES OU LE CODE ÉLECTRIQUE NATIONAL. SI VOUS N’ÊTES PAS LE600A, LE600: Deux lampes LED GU10 Base 7W au maximum FAMILIER AVEC LES MÉTHODES D’INSTALLATION DE CÂBLAGE ÉLECTRIQUE, RECOURREZ L600: Deux lampes Halogen GU10 Base 50W au maximum AUX SERVICES D’UN ÉLECTRICIEN QUALIFIÉ.
  • Page 10 Cette garantie ne couvre pas les coûts d'expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d'expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 11 Interrupteur du lampe 5S4199018 Plaque d’interrupteur 5S1142010 Bouton 5S1142011 Assemblement de support de lampe GU10 5S1137702 Lampe de 7 watts LED (LE600A, LE600) 5S1999726 Lampe de 50 watts Halogen (L600) 5S1137038 Filtre anti-graisse 5S1137041 Assemblement de fils (LE600, L600) 5S1157100...
  • Page 12 REMARQUE www.airkinglimited.com 6727921 Rev. F 12-18 12 of 12...

Ce manuel est également adapté pour:

Le600L600