Télécharger Imprimer la page

Ariston TD 720 MT Instructions Pour L'installation Et L'emploi page 14

Plans de cuisson à encastrement 70

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
The following instructions are intended for the installer so
that the installation and maintenance procedures may be
followed in the most professional and expert manner
possible. Important: Disconnect the appliance from the
electrical supply before performing any maintenance
or regulation upkeep work.
Positioning the Cooktop
Important: this unit may be installed and used only in
permanently ventilated rooms in accordance with British
Standard Codes Of Practice: B.S. 6172 / B.S. 5440, Par.
2 and B.S. 6891 Current Editions. The following
requirements must be observed:
a) The room must be fitted with a ventilation system which
vents smoke and gases from combustion to the outside.
This must be done by means of a hood or electric
ventilator that turns on automatically each time the hood
is operated.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
b) The room must also allow for the influx of the air needed
for proper combustion. The flow of air for combustion
purposes must not be less than 2 m³/h per kW of installed
capacity. The supply of said air can be effected by means
of direct influx from the outside through a duct with a
inner cross section of at least 100 cm² which must not be
able to be accidentally blocked. Those appliances which
are not fitted with a safety device to prevent the flame
from accidentally going out must have a ventilation
opening twice the size otherwise required, i.e. a minimum
of 200cm² (Fig. A). Otherwise, the room can be vented
indirectly through adjacent rooms fitted with ventilation
ducts to the outside as described above, as long as the
adjacent rooms are not shared areas, bedrooms or
present the risk of fire (Fig. B).
Detail A
A
Examples of ventilation holes
for comburant air.
Fig. A
Installation Instructions for built-in
Directly to the Outside
Adjacent
Room to be
Room
Vented
Enlarging the ventilation slot
between window and floor.
Fig. B
c) Intensive and prolonged use of the appliance may ne-
cessitate supplemental ventilation, e.g. opening a window
or increasing the power of the air intake system (if
present).
d) Liquidified petroleum gases are heavier than air and, as
a result, settle downwards. Rooms in which LPG tanks
are installed must be fitted with ventilation openings to
the outside in order to allow the gas to escape in the
event of a leak. Therefore, LPG tanks, whether empty or
partially full, must not be installed or stored in rooms or
spaces below ground level (cellars, ect.). It is also a good
idea to keep only the tank currently being used in the
room, making sure that it is not near sources of heat
(ovens, fireplaces, stoves, etc.) that could raise the internal
temperature of the tank above 50°C.
Installation of Built-in Cooktops
The gas cooktops are equipped with type X degree
protection against overheating. Therefore, the appliance
can be installed next to cabinets, provided the height of
the cabinet does not exceed that of the hob. For proper
installation of the cooktop, the following guidlines must be
followed:
a) If the cabinet(s) located next to the cooktop are higher
than the cooktop itself, the cabinet(s) must be installed
at least 600 mm from the edge cooktop;
b) Hoods must be installed in accordance with the
instructions contained in the installation manual for the
hoods themselves, and no less than 650 mm from the
cooktop;
c) The cabinets installed next to the hood must be located
at a height of at least 420 mm from the top, (as shown
in Fig. C).
d) Should the cooktop be installed directly under a
cupboard, the latter should be at least 700 mm
(millimetres) from the top, as shown in Fig. C.
e) The dimensions of the cutout for the appliance must
be those indicated in the figure.
14
HOOD
600
Min.
mm.
Fig. C
555 mm.

Publicité

loading

Ce manuel est également adapté pour:

Td 720 mstTd 730 mtTd 730 mstTd 740 mtTd 740 mstTo 740 as