Télécharger Imprimer la page

NAIM SuperLine Manuel De L'utilisateur page 4

Publicité

Les langues disponibles

Les langues disponibles

SuperLine In sta ll a tio n
3. 4 C art ridg e Lo ad in g
The resistive and capacitive input load presented by
the SuperLine to the pick-up cartridge can be adjusted
by inserting a combination of "load plugs" into the
appropriate sockets in the rear panel.
The appropriate load plug combination will depend on
both the manufacturer's recommendations for the pick-up
cartridge in use and subjective preference.
Each load plug is constructed from a 5-pin DIN plug that
contains the appropriate passive components. A label on
each load plug identifies its load value.
Seven standard load plugs are supplied - four resistive
and three capacitive - to provide 20 combinations
3. 5 C art ridg e Lo ad P lu g C o mbi n at ion s
Resistance
Capacitance Comments
10kΩ
100pF
10kΩ
1nF
10kΩ
4.7nF
10kΩ
10nF
1kΩ
100pF
1kΩ
1nF
1kΩ
4.7nF
1kΩ
10nF
500Ω
100pF
500Ω
1nF
Note 1:
Approximates to a Naim 'K' load (560Ω and 1nF).
4 Super Line Co nnec tio ns
4. 1 S up erLine Re ar
pick-up arm
ground
resistive
load plug
socket
2
Internal load only. No plugs fitted.
No resistive plug fitted.
No resistive plug fitted.
No resistive plug fitted.
No capacitive plug fitted.
No capacitive plug fitted.
Note 1
BNC input
phono input
sockets. Ch.
sockets. Ch. 1
1 - left, Ch. 2
- left, Ch. 2 - right
- right
capacitive
load plug
socket
(including the default input loads applied when no load
plugs are inserted). Table 3.5 lists the standard load plug
combinations.
Note:
In addition to the standard load plugs supplied, 470Ω
and 560Ω resistive plugs are also available on request.
Other values may also be created either by modifying
standard plugs or manufacturing new ones. Contact your
retailer or local distributor for more information.
Always ensure that resistive and capacitive load plugs are
inserted in the correct socket.
Note:
The SuperLine incorporates 10kΩ resistance and
100pF (0.1nF) capacitance loads internally. With no load
plugs fitted these values constitute the default load.
Resistance
Capacitance Comments
500Ω
4.7nF
500Ω
10nF
220Ω
100pF
220Ω
1nF
220Ω
4.7nF
220Ω
10nF
100Ω
100pF
100Ω
1nF
100Ω
4.7nF
100Ω
10nF
to Supercap
power supply
Note:
SuperLine output
is muted for 2 minutes
following switch-on to
allow its circuitry to reach
optimal status.
to amplifier power
supply output or to
Hi-Cap or Flatcap
power supply
No capacitive plug fitted.
No capacitive plug fitted.

Publicité

loading